Menu

An expert resource for medical professionals
Provided FREE as a service to women’s health

The Alliance for
Global Women’s Medicine
A worldwide fellowship of health professionals working together to
promote, advocate for and enhance the Welfare of Women everywhere

An Educational Platform for FIGO

The Global Library of Women’s Medicine
Clinical guidance and resourses

A vast range of expert online resources. A FREE and entirely CHARITABLE site to support women’s healthcare professionals

The Global Academy of Women’s Medicine
Teaching, research and Diplomates Association

This chapter should be cited as follows:
Linton, A, Kiley, J, Glob. libr. women's med.,
(ISSN: 1756-2228) 2017; DOI 10.3843/GLOWM.10385
This chapter was last updated:
January 2017

Use and Effectiveness of Barrier and Spermicidal Contraceptive Methods

Authors

INTRODUCTION

The prevention of pregnancy is an integral part of modern medical practice and is of major public health interest. In 2012, approximately 85 million women worldwide experienced unintended pregnancies.1 Methods for controlling fertility are necessary and desired. Traditionally, the practice of family planning centered almost exclusively on the prevention of unwanted conception. The goal of modern family planning has shifted towards providing more complete women’s reproductive health, providing women with effective contraceptives with consideration of on-contraceptive benefits and lifestyle advantages of different methods.2 In particular, family planning has the ability to address the dual threats of unintended pregnancy and prevention of sexually transmitted infections. In 2014, the Centers of Disease Control and Prevention (CDC) and Office of Population Affairs included sexually transmitting infection (STI)/HIV testing, treatment, and prevention as a core component of family planning care.3

There are over 20 diseases that may be acquired during sexual relations.4 From an infectious epidemiology perspective, at the time of coitus, a person is potentially exposed to the STI status of all previous mates of his or her current consort. Theoretically, during a single instance of unprotected coitus, a woman could become pregnant and be infected with all STIs. Disparities exist in the acquisition of STIs, with women more susceptible than men to HIV, as well as other infections. Several factors contribute to this inequality; biological factors include differences in reproductive anatomy predisposing women to higher rates of infection, and social factors include problems in controlling the timing of intercourse, issues with partner infidelity, and gender inequality.5

The widespread dissemination of STIs including HIV/AIDS requires intervention by policymakers, health care providers, and patients alike. In the United States, there are approximately 20 million new STI infections annually, with the annual incidence of gonorrhoea and chlamydia on the rise.6 Worldwide, approximately 1 million STIs are acquired daily.7 In addition to many STIs having their own reproductive health consequences, coinfection with other STIs has been found to greatly facilitate HIV transmission.8, 9, 10 As of 2014, an estimated 36.9 million people were living with HIV worldwide. Over the last 15 years, the rate of individuals newly infected with HIV has slowed, however, approximately 2 million people are newly infected each year.11 Given concerns regarding long-term consequences of STI infections and facilitated transmission, interest in contraceptives offering dual protection from unintended pregnancy and STI acquisition has increased.12, 13 Anxiety about the magnitude of the progression of HIV and STI infections has motivated even some Catholic authorities, always in opposition to contraception, to consent to their use to some extent.14

Barrier contraceptives were long considered the best way of providing dual protection; however, this protection was not absolute.15, 16 Increased interest in dual protection has led to re-evaluation of the social and public health impact of mechanical and chemical contraceptives, and pushed for the development of more effective and novel dual protection approaches. Because of the difficulty of carrying field studies in the United States (e.g. cost, reluctant very movable population, liability concerns related to side effects and contraceptive failures, not always related to the use of the product being tested), domestic data on new contraceptives are often scarce. Development of new contraceptives and products that are safe, effective, and acceptable to consumers is a long, tedious, and arduous process, usually taking decades. Though development and testing of such methods is underway, barrier methods remain vitally important in helping mitigate the impact of the health crisis caused by HIV and other STIs. They continue to be widely available, and are often the most accessible option for women desiring dual protection.

CHARACTERISTICS OF BARRIER METHODS AND DETERMINANTS OF CONTRACEPTIVE EFFECTIVENESS

Barrier contraceptives are devices that physically prevent dissemination of sperm in the vagina, blocking the access of spermatozoa to the upper genital tract. Spermicides are pharmaceutical agents containing chemicals that kill or incapacitate sperm administered vaginally in a vehicle (gel, foam, cream, suppository, or film).17 Table 1 lists the common physical and chemical barrier methods of contraception. Barrier and spermicidal methods of contraception are coitus-dependent; all are temporally associated with sexual intercourse. All are female-dependent methods, except for the male condom. Barrier methods and spermicides may be used alone or in combination with one another. Spermicides are often used in conjunction with barrier methods.

Table 1. Barrier contraceptives and spermicides

 Physical barrier methods
 Male condom
 Female condom
 Diaphragm
 Cervical cap/Lea’s shield
 Contraceptive vaginal sponge
 Chemical methods
 Spermicidal gels, jellies, creams
 Vaginal foams, films, suppositories, tablets


Although there are marked differences among various barrier methods of contraception, there are also some similarities. They are intimately associated with the users' sexuality and sexual behavior. Each sexual encounter provides a unique situation in which the partners must decide whether to use the method. One or both partners must make a decision and take action before every episode of sexual intercourse. Therefore, barrier contraceptives demand substantial motivation and necessitate cooperation from the partner.

The decision to comply with a contraceptive method depends on the perceived risk of becoming pregnant, the desire to avoid pregnancy, and numerous other factors, such as the need for confidentiality, side effects, cost, self-efficacy, knowledge of how a contraceptive works, and noncontraceptive benefits. For many people, the successful and consistent use of barrier methods necessitates a change in sexual behavior.2, 18

Safety and effectiveness of barrier methods

Barrier contraceptives are very safe. They are used inconsistently more often than noncoitus-dependent methods. Barrier contraceptive methods continue to be the primarily recommended method for the prevention of STDs and HIV, making them important for ensuring reproductive health. Finally, barrier contraceptives make an important contribution to family planning and public health because they are safe, have no systemic side effects or risks, are effective when used properly, and play a prominent role in the prevention of STDs.19, 20

Barrier methods are reputed to be less effective than other methods. However, they have a significant historical role in the process of making contraception universally available.21 Most of them can be distributed easily through community-based organizations and women's health maintenance groups, and in developing countries by social marketing programs through existing commercial outlets. They extend the accessibility of reliable contraceptives to a greater number of people than ordinarily would be reached by the formal healthcare system. In particular, the male condom has been shown to reduce the spread of HIV infections in large populations, translating into significant public health benefits.22, 23

There are two common measures of how a contraceptive works: efficacy with perfect use (how it performs with correct and consistent use) and efficacy with typical use (which includes both incorrect and inconsistent use).2 Overall efficacy depends on many factors: frequency of intercourse, fecundity of the users, how the method is used, and the quality of the product. But more than for other birth-control methods, the efficacy of barrier methods depends on how well couples use them.24 A method that is rated as less effective could actually be more effective for a particular couple if they use it correctly and regularly. Most contraceptive failures can be ascribed to inadequate compliance or misuse of the prescribed regimen. Barrier contraceptives and condoms used correctly at every episode of sexual intercourse are very effective in preventing pregnancy.2, 25

The reported range of failure or pregnancy rates for barrier methods is vast, from 2 to 32% of women experiencing an unintended pregnancy in the first years of use, depending on the study, the method, and the population.2, 25 The best results are shown in clinical studies using exacting patient selection with considerable input of resources to diminish follow-up losses, reinforce instructions, counter weak motivation, and increase compliance by encouraging correct and consistent use, thus increasing the reliability of the data. Couples available for the follow-up required for clinical studies are often not representative of patients most likely to benefit from them. Thus, the results of most clinical studies tend to be better than the actual performance of any given method during general population use, when a method is more subject to human error and inconsistent behavior. Clinical studies of contraceptives are subject to investigator and participant biases, and study endpoint of use effectiveness should be viewed with caution. Measured thus imperfectly, the generally credited failure rates of various contraceptive methods are shown in Table 2. The physician prescribing a contraceptive should take into consideration the patient's lifestyle and preferences and must be nonjudgmental and unbiased in discussing the benefits and disadvantages of the methods available. Occasionally, physicians are criticized for their involvement in providing contraceptive advice, education, and prescription; however, more criticism is deserved for physicians who ignore an opportunity when contraceptive advice was pertinent, needed, and even requested.

Table 2. Percentage of women experiencing an unintended pregnancy in the first year of use, United States

Method

Typical use (%)

Perfect use (%)

No method

85

85

Spermicides

28

18

Withdrawal

27

4

Fertility-awareness based methods

24

 

Standard days method

 

5

Two day method

 

4

Ovulation method

 

3

Diaphragm

12

6

 
Sponge

   

Nulliparous women

16

9

Parous women

32

20

 
Condom

   

Female

21

5

Male

15

2

 
Hormonal contraception

   

Combined pill and minipill

8

0.3

Evra patch

8

0.3

NuvaRing

8

0.3

Depo-Provera

3

0.3


Intrauterine contraception

   

ParaGard (copper T)

0.8

0.6

Mirena (levonorgestrel)

0.2

0.2

Implant

0.05

0.05

Female sterilization

0.5

0.5

Male sterilization

0.15

0.1

Modified from: Trussell J. Contraceptive failure in the United States. Contraception 2011;83(5):397-404.



Barrier methods' effectiveness as contraceptives and in STD and HIV prevention is enhanced by their consistent and correct use. Frequently, these methods are overlooked and not prescribed; more often, people may fail to use them, change to other methods, or abandon their use and switch to no contraception, resulting in more user failures.26 Conversely, a desire for the privacy offered by some barrier methods made them more acceptable, especially to women who are not willing to admit their sexual activity or will not consult a physician and be examined without having a health problem. For many potential users, the imminence of coitus and the fear of pregnancy are the only stimuli sufficiently powerful to arouse interest in contraception. Most barrier contraceptives are available over-the-counter without a prescription, do not necessitate a physical examination, and, for some people, in certain particular circumstances, may be the best or only effective method available. The correct and consistent use of barrier and spermicidal methods of contraception is determined by the complex interaction of the inherent attributes of the method, user characteristics, and situation. Method attributes include the extent of interference with sexual spontaneity and enjoyment, the amount of partner's cooperation required, and the ability of the method to protect against unwanted pregnancy, STDs, and HIV. User characteristics include motivation to avoid unintended pregnancy, fear of contracting an STD, ability to plan, cultural and religious attitudes regarding sexuality and contraception to which she is subjected, comfort with sexuality, and previous contraceptive experience. Characteristics of the relationship, stage of reproductive career, and previous sexual experiences are important situational influences. User preferences are critical considerations for practitioners recommending a contraceptive method, especially one that requires motivation for proper use.27

Obtaining valid estimates of the reduction in STD transmission conferred by barrier contraceptive use is challenging,28, 29, 30 but it is clear that condoms provide significant protection from STDs, even with imperfect use.22, 23, 31 Other barrier and spermicide methods are reported to provide protection against STDs and pelvic inflammatory disease.32, 33, 34 Their use has been associated with lower rates of cervical cancer than other methods of contraception.35, 36 Women who never use barrier methods have twice the chance of having cancer of the cervix develop.37 Barrier methods also contribute to the prevention of infertility, likely secondary to their protection from pelvic infections.33, 34 A rare problem associated with the use of certain barrier contraceptives is toxic shock syndrome (TSS), an uncommon but potentially fatal systemic infection with Staphylococcus aureus. Occurrences of TSS associated with the diaphragm and contraceptive sponge have been reported.38 However, the actual risk is exceedingly rare, with the annual incidence of TSS from any etiology of less than 1 per 100,000.39

Choice of contraceptive methods

Although their characteristics vary widely, each contraceptive method in use today has limitations. As such, there are currently gaps in women's ability to control fertility safely, effectively, and in culturally acceptable ways throughout their reproductive lives. The consistent use of barrier contraception depends on a woman's perception of her risks of pregnancy and sexually transmitted infection with each act of intercourse, and these risks may not be equally important to every woman.2, 40 Although a woman's fertile period is limited, no woman knows exactly when ovulation occurs, so women should be advised to use contraception at all times. A woman is fertile only a few days every menstrual cycle. The chance of pregnancy after any one act of sexual intercourse has been estimated to be approximately 3–4.5%.41

The main considerations against the acceptability of barrier contraceptives are the necessity for touching the genitalia, messiness, storage, resupply, disposal, and direct relation to coitus. Some methods are bulky and difficult to store, carry, and use discreetly. In addition, planning and motivation are required to ensure consistent use. All these challenges occur to some extent with most users in most cultures.42

Contraceptive methods are complementary, not competitive. Each method offers a different balance of advantages and disadvantages, and the physician should be ready to advise or prescribe another method when the patient is not satisfied with the current one. The prescription or fitting of a contraceptive device should always be accompanied by thorough instructions for its proper use. Never assume the patient understands the correct use of the method chosen, and consider that the printed material for most contraceptives is usually above the level of literacy of the intended audience.43 Functional health literacy influences contraceptive understanding, attitudes, and behavior, and low literacy levels are a problem in family planning clinics.44, 45 Women with more education are better able to control their own sexuality. More education is associated with better health outcomes, a lower number of pregnancies, and lower infant and maternal morbidity and mortality, as well as higher life expectancy.

Reproductive health involves not only the prevention of unintended pregnancy but also of STDs, especially HIV. To increase the degree of prevention, it is appropriate under many circumstances to recommend simultaneous use of two contraceptive methods (e.g. systemic hormonal contraceptives or IUDs and condoms, or sterilization and condoms). In fact, dual method use is widely advocated and has been the subject of intensive research in recent years.12, 13, 15[46 It has been speculated that emphasizing the important advantage of disease prevention increases the acceptability of condoms and their consistency of use. Patients usually attach different priorities to preventing pregnancy or STDs, and these priorities may change over time and among relationships.2, 47, 48

GENERAL INDICATIONS FOR BARRIER METHODS

Barrier contraceptives are indicated for: (1) women in whom other forms of contraception are contraindicated; (2) women who prefer a reversible contraceptive method without hormonal effects or requiring implantation of a specialized device; (3) women seeking an interim method until hormonal or intrauterine contraception is initiated or sterilization is performed; (4) women during lactation and the puerperium, often as an adjunct to lactational methods; (5) women who elect to use barrier methods for infrequent episodes of intercourse; (6) women who plan to conceive in the near future; and (7) women at risk for sexually transmitted infection, who may elect to use barrier methods alone or in conjunction with another contraceptive method (dual method use).

 

 

 

MALE CONDOMS

The condom (also known as a prophylactic, rubber, sheath, or French letter) is the only widely available male method of contraception available besides coitus interruptus (withdrawal) and male sterilization. It is one of the oldest and most extensively used contraceptives. Variations of the condom have been used for thousands of years to prevent conception and infection; however, it was first formally described by anatomist/physician Gabriel Falloppio in the 16th century as a way to prevent syphilis.49 The worldwide upsurge of STDs as well as the unstoppable pandemic of HIV/AIDS contributed to dilute most of the reservations about condoms and its use held by society at large. Because of its excellent record of infection prevention and contraceptive protection, its availability, and its simplicity of use, the condom has become a cornerstone of family planning care. It offers protection against unintended pregnancy and serves as the greatest defense against STD transmission; its historical role in the prevention of STDs is unmatched by any other method of contraception.

 

Benefits and limitations

There is consistent clinical evidence from prospective studies of discordant couples, in which one partner is infected with HIV and the other not, that latex condoms used correctly during every act of sexual intercourse are very effective, not only in preventing unintended pregnancy, but also in HIV transmission.22, 23 When used correctly during each sexual act, condoms are very effective in preventing unintended pregnancies and STDs. In this dual capacity, condoms may be regarded as the contraceptive gold standard against which all other contraceptive methods might be compared. In strict comparison, most other contraceptive methods fall short, because of their lack of ability to prevent sexually transmitted infection. Consider the specifications for an ideal contraceptive: high effectiveness, safe, reversible, inexpensive, free from side effects, small and inconspicuous, aesthetically acceptable, self-administered, simple to use, requiring no special skills or professional intervention, easy to store and distribute, offers STD prevention, long shelf life, and use independent of sex. Male condoms answer with ease all those requirements except the last, although the last criterion presents a major hurdle in effectiveness.50 Additionally, condoms play an important role in rare cases in which women are hypersensitive (atopic allergy) to contact with semen.

Male condoms confer several benefits. They are widely available, easily obtainable, and reasonably inexpensive (even provided without charge by many family planning and STD clinics and some student health services). Condoms are frequently distributed through public health campaigns and programs, increasing their availability.51, 52 They do not require prescription or fitting. Condoms have virtually no contraindications or side effects, except in persons with preexisting allergies to latex rubber or lubricant.53, 54 Problems possibly related to being powdered with talc have been reported.55, 56 Condoms are inconspicuous. They are simple to use, and their use is easy to teach and understand, even by people with limited education. Condoms can be used for sporadic or unanticipated coitus, or by those who have infrequent intercourse. Condoms are a viable method for couples who wish to share the responsibility for contraception, as well as when immediate assurance of successful protection against conception is psychologically important to either partner. They are valuable as an interim method before hormonal contraception is initiated or intrauterine contraception is inserted or sterilization is performed. Table 3 lists the indications and contraindications for male condom use.

 

Table 3. Indications and contraindications for male condom use

Indications

Male

Female

Both

Genital or penile disease, including active sexually transmitted infection

Contraindications to hormonal or intrauterine contraception

Uncertain partner fidelity

Sensitivity or allergy to vaginal secretions

As 'backup' method when use of other contraceptive methods (e.g. oral contraceptive or injectable) is suboptimal

Male contraceptive control preferred

Temporary use while awaiting vasectomy

Temporary use when initiating hormonal contraception, or awaiting intrauterine contraception or sterilization

Risk of sexually transmitted infection

Premature ejaculation

Genital tract infection, including active sexually transmitted infection

Spontaneous sexual encounter or infrequent intercourse

 

Vaginitis, including vaginitis under treatment

Active or suspected sexually transmitted infection

 

Desires assurance that semen was not released into vagina

History of inactive viral sexually transmitted infection

 

Aversion or allergy to contact with semen

 

 

Psychological, cultural, or religious conflict with personal use of contraception

 

 

Postpartum

 

 

CONTRAINDICATIONS

Allergy to latex in either partner

Either partner unable or unwilling to use condom consistently

Modified from: Sobrero AJ Sciarra JJ: Contraception, In Cohn HP (ed): Current Therapy 1978, Baltimore, WB Saunders Company, 1978

 

Drawbacks or perceived negative attributes of the condom are its historic connection with illicit sex, promiscuity, and distrust of the partner's health.57 Like all barrier contraceptives, condoms necessitate persistent, recurrent motivation to achieve dependable protection against pregnancy and sexually transmitted infection. They must be used correctly at each sexual engagement. A commonly mentioned drawback is the need to interrupt intercourse for placement; however, couples may surmount this by making the placement of the condom part of the sexual experience.

 

Contraceptive effectiveness and protection against infection

Condoms are made of latex rubber, polyurethane, and natural membranes (Lamb's cecal pouch). Most commercially available condoms are made of latex rubber. They come in an astounding variety of shapes (e.g. blunt or with a reservoir tip, ribbed, speckled, peppered with dots, contoured, with a helix or spiral rib, with a loose pouch over the glans or the penile shaft). Condoms come in an assortment of colors, combinations of colors, even fluorescent, and they may be flavored. They come in different sizes: standard (170 mm long and 50 mm wide), long (30% longer), extra-large (45% larger), narrower (6%), and shorter (15%). They come as extra-strength and extra-thin. They may be lightly powdered or lubricated with silicone or a water-soluble spermicide or without spermicide, or a desensitizing product. Their variety seems to be limited only by the imagination of the manufacturers. Indications are that there is a market for such diversity and attesting to the contemporary losing of old social restraints about sexual intimacy. Usually, condoms are neatly rolled and packaged flat in paper, plastic, or aluminum foil. They have a long shelf-life, especially if they are protected from direct sunlight, heat, oily substances, and ozone, all of which contribute to rapid latex deterioration.

Effectiveness of the male condom is associated with user ability, sexual practices, propensity for breakage, and issues related to manufacturing. No studies demonstrate that condoms lubricated with a spermicide are more effective than unlubricated condoms in preventing pregnancy. Problems of slippage occur more often with lubricated than non-lubricated condoms. Regarding sexual practices, vigorous coitus appears to increase ruptures. Reported figures on the incidence of condom breakage/slippage range between 1 and 11% of uses, with the majority of studies evidence suggesting an incidence between 1.6 and 3.6% of coital acts.58, 59, 60, 61, 62

During manufacture, condoms must meet the stringent standards set by ASTM International and International Organization for Standardization (ISO). In conjunction with the ISO and multiple other international agencies, the World Heath Organization releases a manual describing the guidelines for ensuring quality condoms, including specifications for latex type, appropriate shelf lives, minimum bursting volumes and pressures, electronic testing for identification of microscopic holes, water leak tests, and even packaging specifications.63 In many countries, including the United States, condoms are imprinted with the date of manufacture or an expiration date. Aging is a major predictor for condom breakage, so patients must be advised to discard condoms when past their expiration date.64, 65 However, equally important are the manufacturer's packaging and storage procedures and the user's appropriate handling at the time of intercourse.66

Latex condoms theoretically form a continuous, impervious barrier to bacteria and viruses, though in reality, it is impossible for this barrier to be 100% impenetrable. One FDA study found that fluorescent polystyrene microspheres (110 nm) similar in diameter to the HIV virus (90–130 nm) could pass through 29 of 89 unlubricated latex condoms. The harsh physical conditions of the in vitro test under which the study was performed included 30 mL of a watery suspension of particles at a concentration 100 times that reported for the average normal human ejaculate (3 mL) under high pressure over 30 minutes. Based on the rigorous nature of study conditions, the authors acknowledge that their findings likely represent a worst-case scenario for the risk of fluid transfer with condoms, which is still at least 10,000 times better than not using a condom at all.67 Women who are partners of HIV-positive condom users are less likely to seroconvert than those whose partners did not use condoms.22, 23 A recent review of 25 studies with almost 11 thousand HIV serodiscordant heterosexual serodiscordant couples analysed showed that condoms reduced HIV transmission by more than 70% when used consistently.22

Most users of condoms are more worried about avoiding unwanted conception than preventing an STD; however, this important personal and public health aspect of barrier contraception should not be relegated to a secondary role. It is worthwhile to emphasize that the prevention of STDs may prevent future infertility33, 34 and cancer of the cervix.35, 36 Reasons for inconsistent condom use among 18–24 years old college students exemplified wide variations in perceived risk (for pregnancy and STIs), substitution for less effective alternatives (such as withdrawal), and priority of avoiding unpleasant side-effects (condom smell, decreased sensation) over prevention of pregnancy/STIs.68 Much contemporary research focuses on access to condoms and reasons for use and non-use in various domestic and foreign populations.69, 70, 71, 72

Nonoxynol-9 (N-9), the spermicide used in many lubricated condoms, causes release of a natural rubber latex protein that may increase the risk of allergic reaction in individuals with latex hypersensitivity.53, 73 Although theories suggest that latex condoms increase the risk of developing latex allergy, studies show that exposure to condoms does not increase the risk of subsequent latex allergy.74 For latex-sensitive persons, condoms with or without N-9 may cause an allergic reaction.75 However, overall latex allergy associated with barrier contraceptive use is rare.

Latex-free and deproteinized latex condoms are good alternatives for latex-allergic patients.76, 77 Male synthetic condoms are manufactured using a dipped process similar to latex condoms or a cut-and-seal process using a synthetic elastomeric film. They are less elastic and wider than latex condoms, making them less constrictive. Avanti (London International Group, London, U.K.) is a popular, commercially available synthetic male condom, FDA-approved in 1991. It is made from Duron, a thermoplastic polyester polyurethane, and it is straight-sided and reservoir-tipped. It is wider, approximately 64 mm when lying flat versus 52 mm for the standard latex condoms. Tactylon (Sensicon Corp., Vista, CA), another plastic condom produced by the dipping process from another synthetic elastomer, has been cleared by the FDA, but it is not found commercially. Three Tactylon models were manufactured (standard, baggy, and with a wider closed end of 80 mm) to allow greater comfort by diminishing glans constriction and to provide a more elastic, standard shape condom. Ezon (Mayer Laboratories, Oakland, CA) is another synthetic elastomeric condom, but it is not cleared by the FDA. It bears a unique design. Rather than being rolled on like latex condoms, Ezon is slipped onto the penis. Trojan Supra (Carter-Wallace Inc., New York, NY) is polyurethane male condom, FDA-approved and commercially available in the United States. It is somewhat larger than most condoms, measuring 189 mm long and 59 mm wide.78 According most reports, synthetic condoms break and slide more often than latex condoms.77, 79, 80, 81 A recent Cochrane review comparing latex-free and latex condoms reported that non-latex condoms are an acceptable alternative to latex condom use when indicated, despite higher rates of clinical breakage. The authors noted that the contraceptive efficacy of non-latex products needs further investigation.77

Natural membrane condoms made of lamb cecum are also available. They fit loosely on the penis and conduct more heat than latex condoms, supposedly providing more sensitivity during intercourse. Their thicknesses are variable but similar to that of rubber latex condoms (approximately 0.07–0.08 mm). They are considerably more expensive than their latex counterparts. These condoms must be kept moist to prevent cracking of the animal membrane, so they are packaged with water-based lubricant. Laboratory tests show that natural membrane condoms contain micropores that allow passage of HIV, hepatitis B virus, and herpes simplex virus, and thus they are not indicated for STD prevention. No use-effectiveness data are available on natural membrane condoms, but they have been shown to prevent the passage of sperm and are permitted by the FDA to be labelled for pregnancy prevention.78, 82

In recent years, much deserved attention has centered on the ability of N-9 to prevent HIV transmission. Disruption of the vaginal and upper reproductive tract epithelium by N-9 was demonstrated in animal and human studies.83, 84 Concern developed that N-9 actually increased HIV transmission, due to viral entry through microscopic lesions in the vaginal mucosa caused by the spermicidal agent. A 2003 World Health Organization report summarized the research findings on use of condoms with N-9 lubricant. The committee concluded that condoms with N-9 were not more effective than condoms alone in pregnancy prevention, and that such condoms should not be encouraged for use. Use of condoms with N-9, however, was better than using no condom at all. N-9 was found to increase the risk of HIV transmission in high-risk women, but it remains a contraceptive option for women at low risk of HIV infection.85

Some research suggests an association between male condom use and urinary tract infection (UTI) in females. Condoms lubricated with N-9 have been associated with an increased frequency of UTIs versus condoms without the spermicide,86 and others conclude that non-lubricated condoms are also associated with UTI.87

The first-year failure rates for male condoms with typical use is usually quoted as 15% in the United States.19 Data from the 2002 National Survey of Family Growth document a 17.4% pregnancy rate in the first year of condom use. Risk factors for condom failure included younger age, multiparity, non-Hispanic black race, and poverty.88 The contraceptive effectiveness of the condom is acknowledged to be less than that of oral contraceptives, hormonal injections, implantable contraceptives, and intrauterine contraception. However, condoms used consistently and correctly are highly effective at preventing pregnancy, with perfect-use failure rates of only 2%.19

Clinicians, counselors, educators, and public health advocates all serve as sources for encouraging proper condom use. All must be familiar with the instructions for condom use and be able to direct patients appropriately (Table 4).

 

Table 4. Instructions for proper male condom use

For prevention of STD transmission, use condoms made of latex rather than natural membrane, except in cases of latex allergy

Do not use torn condoms, those in damaged packages, or those with signs of age (brittle, sticky, discolored, past expiration date)

Place the condom on the penis before it touches a partner's mouth, vagina, or anus

Place the condom on the penis when it is erect. Make sure you have the rim side up so you can unroll it all the way down to the base of the penis, before the penis comes in contact with a body opening

Leave a space at the tip of the condom to collect semen; remove air pockets in the space by pressing the air out towards the base

Use only water-based lubricants. Lubricants such as petroleum jelly, mineral oil, cold cream, vegetable oil, or other oils may damage the condom

Replace a broken condom immediately

After ejaculation and while the penis is still erect, withdraw the penis while holding the condom carefully against the base of the penis so that the condom remains in place

Do not reuse condoms

Modified from: Fox CE. Clinician's Handbook of Preventive Services, 2nd edition. U.S. Department of Health and Human Services, U.S. Government Printing Office, 1998

 

Although issues exist with consistent method use, the dual function role of male condoms in preventing pregnancy and sexually transmitted infection must be emphasized. Currently, the condom is the only widely available method providing dual protection, and this importance must be conveyed to users for promotion of individual and public health.

 

FEMALE CONDOM

The female condom offers female-controlled dual protection against STDs and pregnancy, and thus is an important recent development in barrier contraceptives. First introduced in Europe in 1992, they were first approved for use in the United States in 1993. The most widely available condoms internationally include:89

  • FC2®(brand names include Reality, Protectiv, Femidom, Care) – manufactured by Female Health Company, Chicago, IL
  • VA w.o.w.®(brand names include Reddy, V’Amour) – manufactured by Medtech Products Ltd, Chennai, India
  • The Woman’s Condom (brand names include O’Lavie) – manufactured by Dahua Medical Apparatus Company, Shanghai, China in conjunction with PATH, Seattle, Washington
  • Phoenurse® – manufactured by Tianjin Condombao Medical Polyurethane Tech. Co. Ltd, Tianjin, China
  • Cupid – manufactured by Cupid Ltd, Nashik, India.

The FC2® is currently the only US FDA approved female condom. New designs and updates continue to emerge and be tested.90, 91

In addition to the benefits of female control, female condoms carry the advantage that they can be inserted up to 8 hours prior to coitus.92, 93 Many female condoms are made of polyurethane, which is hypoallergenic, stronger, and more resistant to heat than latex condoms, and is not sensitive to oily lubricants or storage under conditions that would damage rubber latex condoms.94 The FC2® is made of nitrile (synthetic latex), which has similar properties.89

The female condom (Fig. 1) consists of a soft, medical-grade polyurethane (or similar) sheath open at one end and closed at the other. It has two flexible rings (often of the same material), one at each end. The external open ring is designed to stay outside the vagina, resting against the vulva. The inner ring, at the closed end of the sheath, is firmer and must be inserted into the vagina. The majority of female condoms are pre-lubricated with silicon-based lubricant (aside from the Woman’s Condom, which is packaged un-lubricated, and expands from a capsule once within the vagina). Insertion of a female condom is facilitated by squeezing the inner ring with one hand while separating the vulvar labia with the other as when inserting a tampon or a diaphragm. Care should be taken not to twist the sheath; otherwise, insertion of the penis will be impossible. The internal ring should be pushed beyond the pubic bone and as close as possible to the cervix. The internal ring, which is not incorporated into the wall of the condom, should not be removed. After intercourse, the open ring should be squeezed and twisted to keep the semen inside without spilling. The device is intended for single use.

 

Fig. 1. Clockwise from top left. (A) Reality female condom. (B) Holding it for insertion. (C) Insertion. (D) Pushing the internal ring beyond the pubic bone, close to the uterine cervix, and (E) the device in place.

The female condom is somewhat more expensive than its male counterpart. However, given the potential impact in reducing HIV infection afforded by a female-controlled method, some donor organizations have contracted with producers to provide the devices at low cost. These social campaigns have negotiated costs of less than one US dollar per device, and some studies indicate that such campaigns are cost-effective.95 Female condoms are also felt to be equally as effective as male condoms at preventing HIV and STI transmission,96 and theoretically may be more protective at preventing genital ulcer diseases given their coverage of the vulva and perineum.

Reuse of the female condom has been reported in many countries, especially those with limited resources. The general recommendation is to use a new condom for each act of intercourse, due to concerns for compromised structural integrity of the condom with handling and washing. Some studies examine the possibility of reuse of female condoms; most found that repeated cleansing of the condoms was associated with structural defects, but usually only after multiple washes.97, 98 In one study, devices were still within FDA standards for structural integrity after repeated washings.98 WHO does not recommend or promote reuse of the device, but acknowledging that access to new condoms may be limited in developing areas, has issued a protocol for the safe cleaning and handling of female condoms for reuse.99, 100

The contraceptive effectiveness of female condoms is similar to that of male condoms and other barrier methods.101, 102 First-year failure rates in the United States are estimated at 5 and 21%, for perfect and typical use, respectively.2 Most users consider the device acceptable, and widespread uptake of female condom use should prove possible with social marketing, directed counselling and increased availability in at-risk populations.103, 104, 105

The female condom offers major potential as a dual-function method, as its effectiveness at preventing pregnancy and sexually transmitted infection is similar to that of the widely accepted male condom. The female condom is a welcome addition to the contraceptive armamentarium. It is acceptable to women of many different cultures and provides its users with credible dual protection under female control.

 

 

CONTRACEPTIVE DIAPHRAGM

Invention of the contraceptive diaphragm is credited to the German gynecologist Wilhelm Mensinga, who described it in 1881.21 It was introduced in America in the early part of the 20th century by the illustrious feminist Margaret Sanger, who brought the diaphragm from Holland upon return from her self-imposed exile. It was popularized by her followers and the family planning movement she initiated as part of her efforts to liberate women from the burdens of undesired pregnancy. The vaginal diaphragm was the first highly effective method of contraception available to women. As such, and for more than 40 years until the advent of oral contraceptives and the intrauterine device, it was the backbone of the family planning movement in the US. The diaphragm was originally used by upper- and middle-class women who had not only the sophistication to recognize their sexual rights, but also the means and privacy to take advantage of them. It placed the contraceptive initiative and responsibility under the control of women. Important advantages of the diaphragm include moderate protection against sexually transmitted infections, lack of systemic side effects, cost-effectiveness, reversibility, and low maintenance, with requirement for only a single physician visit in most cases.106

The original Mensinga vaginal diaphragm consisted of a narrow, flat steel band, forming a ring. Vulcanized rubber completely covered the ring and closed the space, shaping a dome. This domed rubber cup, with no modifications except for improvements in the quality of the rubber and the ring, has remained virtually unchanged as an excellent female-controlled barrier contraceptive. Those constructed with rubber or latex rubber are sensitive to oily substances and lubricants. When properly fitted and placed, diaphragms ride diagonally in the vagina between its posterior fornix and the tissues on the back of the pubic arch.

Types of diaphragms

Diaphragms are available in three general types: coil spring, flat spring, and arcing spring (Fig. 2 and Table 5).106 Most are made of latex or rubber. The flat spring or Mensinga diaphragm allows lateral compression but has no frontal elasticity. The coil spring type has a ring made of coiled steel that permits good lateral as well as limited frontal elasticity. Flat and coil spring diaphragms form a straight line when compressed to insert them. Because of their construction, they offer only lateral elasticity. They are suitable for most women, and they fit well, even when there is moderate vaginal relaxation without cystocele. Arcing spring diaphragms come in two types. The hinged or 'bow-bend' diaphragm has in the core of its steel coil two semicircles of rigid steel that permit it to bending only in one position, forming a pointed arc. It is rigid in the anteroposterior axis and exerts strong lateral pressure. It cannot be fitted in most women with a retroverted uterus. The other arcing diaphragm is the All-Flex. The rim of this diaphragm forms an arch regardless of where it is compressed. It also offers some frontal elasticity. Most women find arcing diaphragms easier to insert because their curving assists in guiding it. They fit well, even in those vaginas with some relaxation or in the presence of a long cervix. The differences among them are only the type of ring and the degree of vaginal support they may offer and the ease of fitting and of insertion and removal by the user. For women with latex sensitivity, the arcing spring and coil spring types include a silicone-derived alternative. These silicone diaphragms are not available from pharmacies and must be ordered from the manufacturers.106

 

Fig. 2. Contraceptive diaphragms. A. Flat spring. B. Arcing spring. C. Hinged spring (arrows indicate hinges ). (From Speroff L, Darney P: A Clinical Guide for Contraception, Baltimore, Williams & Wilkins, 1992)

  Table 5. Types of contraceptive diaphragms

Diaphragm type Brand name Manufacturer Material Sizes (mm)
Flat spring Ortho White Ortho Rubber 55–105
Coil spring Koromex London International Latex rubber 50–95
  Ortho Coil Spring Ortho Rubber 50–105
  Omniflex Coil Milex Silicone 60–95
Arcing spring All-flex Ortho Rubber 55–95
  Koro-flex London International Latex rubber 50–95
  Wide-seal Milex Silicone 60–95

 Modified from: Allen RE. Diaphragm fitting. Am Fam Physician 2004;69:97-100.

Each type of diaphragm offers its own advantages; however, not all women can be appropriately fitted (Table 6). Satisfactory results are obtainable with any of the varieties, provided a good fit is achieved and the woman uses it consistently. A major benefit of the diaphragm is that it is free of systemic side effects.

Table 6. Indications and contraindications for the contraceptive vaginal diaphragm

 Indications

Female control desired

Systemic hormonal contraceptives and IUD contraindicated or unacceptable

Contraindications

Absolute Relative Temporary

Psychological/mental inability to learn correct use

Aversion to touch own genitals

Physical inability to master correct use (e.g. marked obesity, fingers too short)

Poor pelvic support, with severe cystocele, urethrocele, uterine prolapse

History of vaginoplasty, rigid vaginal walls, vaginal malformations, strictures

History of recurrent cystitis

History of toxic shock syndrome

Vaginismus

Need for contraceptive method of greater effectiveness

Lack of privacy

Moderate cystocele or rectocele or both

Dyspareunia

Fixed uterine retroflexion

Chronic vulvar dermatosis, eczema genitalis, genital psoriasis, contact dermatitis

History of cervical dysplasia

History of herpes simplex virus infection

Recent delivery (<12 weeks postpartum)

Recent episiotomy

Acute or subacute vulvovaginitis or cervicitis of any etiology until treated

Cystitis, urethritis, or other genital infection until diagnosed and treated

Modified from: Sobrero AJ, Sciarra JJ. Contraception. In Cohn HF (ed): Current Therapy. Baltimore, WB Saunders Company, 1978.


Diaphragm fitting

Diaphragms are measured by their diameter in steps of 5 mm. They come in sizes from 50–105 mm (Table 5). Extreme sizes are difficult to find; most common are 70–80 mm. Fitting sets generally come with fitting rings, or actual diaphragms, with diameters of 65–85 mm. Using actual diaphragms for fitting instead of fitting rings facilitates the patient's understanding of how the diaphragm works and how it feels when placed in the vagina.

The diaphragm should be selected only after a gynecologic examination and careful assessment of the condition of the pelvic organs. Note the depth and elasticity of the vagina and the tone of vaginal walls and the perineum, as well as the presence or absence of cystocele, rectocele, or urethrocele, and of a recess behind the symphysis pubis. Not infrequently, two women with the same vaginal depth require a different size or type of diaphragm because of marked differences in vaginal wall tone and elasticity. Individual anatomy determines the choice.

One anatomic point of much value in determining the type of diaphragm that can be properly fitted is the condition of the retropubic space. In most women, a well-defined recess is located behind the pubic arch; the anterior part of the diaphragm rim should fit in this space, resting in front against the symphysis. When the anterior vaginal wall is relaxed due to poor vaginal tone or a cystourethrocele, this space is obliterated. In these cases the diaphragm will not fit well and tends to sag. In such cases, the diaphragm cannot be prescribed and another method should be advised.

The proper diaphragm size is the largest one that fits snugly between the posterior vaginal fornix and the retropubic recess without being felt by the patient. If the diaphragm is too small when placed in the posterior fornix, it will not reach the retropubic groove, and if it fits in the retropubic space, it may have been placed onto the cervix without covering it. In both instances, the diaphragm will not form an adequate barrier. When it is too large, it falls anteriorly and causes discomfort, or it may project from the vagina and drop posteriorly, allowing the penis to pass over it during intercourse. In either case, the diaphragm does not provide a barrier, negating its contraceptive value. With correct sizing, only the tip of the index finger tightly fits between the anterior part of the diaphragm rim and the retropubic vaginal mucosa.

Once the appropriate size is found, the patient should be asked to cough or Valsalva to test whether the diaphragm remains in place. The diaphragm forms a partition that divides the genital tract in two sections: the upper including the cervix and the lower serving as the channel for the penis. Inserting the diaphragm with the dome up or down makes no difference as long as it is well fitted. The rubber of the dome wrinkles under the lateral vaginal compression against the ring; this action provides adequate space and elasticity for unimpeded normal coital activity without either partner feeling the device.

In contrast to traditional fitting techniques, several studies have looked at use of a single-size contraceptive diaphragm.107, 108, 109 A multicenter trial of 450 couples found that 98% of women were able to be fitted with the singe-size diaphragm, and that efficacy was similar to the standard diaphragm. The authors suggest that a single-size diaphragm may allow for easier access and provision, eliminating the need for a pelvic exam or formal fitting.110 This non-latex, single-size diaphragm was granted market clearance by the US FDA in 2014, and is now available in over 25 countries worldwide.110

Women requesting the diaphragm should be taught to palpate the cervix and probe the retropubic space where the anterior portion of the diaphragm rim is positioned. Digital palpation of the cervix, how it feels when covered by the rubber, and touching the rim behind the pubic bone are critical steps for her to master. She should be instructed on the important anatomic landmarks and how the diaphragm works. A pelvic model and a diaphragm may be useful for this purpose. Using actual diaphragms during teaching facilitates understanding. The patient learns that the vagina is internally closed and that there is no danger that the device will enter the uterus and be lost in her body, impossible to retrieve. Many women need assurance that the size of the diaphragm has little relation to the amplitude of the vagina.

The patient should be encouraged to practice inserting and removing the diaphragm several times to familiarize herself with the technique. This practice provides confidence about her handling of the device, as well as reassuring the physician about the patient's mastery of the technique. The need for thorough washing of the hands before insertion and removal should be stressed. Consider a follow-up appointment in 1 week, during which the woman should practice insertion and removal at home, leaving it in the vagina overnight or even a full day. Caution should be taken in recommending it for contraception until after proper use is confirmed. Inserting the diaphragm at home might be facilitated by squatting or sitting on a toilet or standing with one foot on a stool or the toilet seat while bending forward. If the diaphragm causes discomfort, it is too large, wrongly inserted, or contraindicated. The success of the method often depends on the care taken to instruct the woman on the proper technique.

Diaphragm use and care

Gels or creams provide lubrication to facilitate insertion of the diaphragm. A lubricant must not contain products damaging to the rubber or irritating to the woman or her partner. Approximately two inches or a spoonful of the spermicidal jelly or cream is placed in the cup of the diaphragm, and some of it is smeared on the rim and the other face of the device. Jellies provide more lubrication. A cream or foam is indicated when less lubrication is desired; foams are less favorable for this purpose. Previously, the adjuvant spermicidal jellies and creams were felt to have potential bactericidal properties and perhaps diminish the risk of acquiring some STIs. While some new promising products are in development,111 current studies have not consistently supported the idea of spermicides for STI protection, and spermicides should not be recommended for use alone for prevention of HIV or other STIs.17

Traditional teaching advocates that the diaphragm and spermicidal agent may be inserted hours before intercourse, but if more than 2 hours elapse, additional spermicide should be placed in the upper vagina for maximal protection from pregnancy. Without any scientific data to support it, removal of the diaphragm is advised after 6–8 hours from ejaculation. The diaphragm may remain in the vagina overnight but not for more than 24 hours. When repeated coitus occurs, a fresh application of the spermicide may be inserted with an applicator or with a finger without removing the diaphragm. A Brazilian study comparing subjects who used a diaphragm without spermicide continuously, with subjects using a diaphragm plus spermicide only at the time of intercourse, demonstrated that the continuous users experienced lower failure rates and were more likely to continue the method.112 However, other studies have suggested higher failure rates when spermicide is not used,17, 113 and thus clear conclusions on the need for adjuvant spermicide cannot be made. For the sexually active woman, insertion of the diaphragm may become part of her daily routine before retiring, because many users prefer to have it in place well in advance of any possible coitus to avoid the need for extemporaneous preparation. To remove the diaphragm, the patient inserts her index finger under the anterior portion of the rim and pulls the device downward and outward.

Diaphragm use during menstruation is typically not recommended, but if it is desired, the diaphragm should not be placed too long before intercourse, and it should be removed shortly afterward. The danger of toxic shock syndrome (TSS) with prolonged retention of the device should be emphasized, because TSS has been described after diaphragm use.114, 115 Although TSS is rare, approximately 95% of cases reported have been temporally related to menstruation.38, 39, 114, 115 Patients should be counseled that prolonged retention and improper fitting can cause vaginal irritation, even mucosal damage.

A major problem in prescribing a diaphragm is the absence of well-trained personnel. Fitting demands skill, patience for teaching, and time (usually 15–20 minutes). Because diaphragms are less popular now than they were historically, adequate supplies (all models and sizes) often are not available in clinics. Another issue is societal in nature; many women are conditioned not to touch or explore their genitals. In some instances, a woman's attitude toward the insertion of tampons may provide insight to her feelings about placing the device in the vagina and ensuring its proper position. Obese women, women with short fingers, and those with manual limitations may not be able to use this method.

If properly maintained, a diaphragm can last several years, making it a cost-effective contraceptive method. After use, the diaphragm should be washed, dried thoroughly, and placed in its container. If desired, it can be powdered with corn starch. However, talcum powder contributes to the rapid deterioration of the rubber. Periodically, the diaphragm should be inspected against a strong light for weak spots or perforations.

Effectiveness

The diaphragm is an effective method of birth control when fit is appropriate and it is used consistently. The degree of effectiveness depends to a large extent appropriate fit and the motivation of the user. Estimates of first-year pregnancy rates in the US with perfect and typical use are 6 and 16%, respectively.19 Failure rates do not differ by parity, compared with the contraceptive sponge or cervical cap.24 One study reported a lower failure rate in women older than 35 years than in younger women. In this study, successful diaphragm users are older and married, have completed their families, are experienced with the diaphragm or other barrier methods, are better educated, and have higher socioeconomic status.116 However, successful use by very young females showed that the method is suitable for all age groups, provided appropriate fit, training, and support are available.24

Insufficient evidence exists to support use of adjuvant spermicidal products to increase the effectiveness of the diaphragm, although the practice is common.17 The spermicide theoretically offers two added contraceptive advantages: spermicidal activity and an additional mechanical obstacle to sperm migration. A superior pregnancy rate of one per 100 woman-years with the continuous use of a 60-mm fit-free arcing diaphragm without spermicide, removing it briefly every day for washing only, was reported.113 A retrospective analysis in Brazil of the same practice found that continuous use carried a lower failure rate than the one found in a group of women using the diaphragm with a spermicide before each act of intercourse.112 It was speculated that the difference was due to the failure of noncontinuous diaphragm users to use the device on every sexual occasion because of the inconvenience of inserting it on demand. In contrast, a prospective British study projected to study 200 volunteers using a fit-free 60 mm diaphragm for 1 year was halted after enrolling 110 women because of a high failure rate—24.1 per 100 woman-years (29.5 for the women without diaphragm experience and 17.9 for women with barrier contraceptive experience). Major reasons for discontinuation, apart from contraceptive failure, were malodor and problems with removal and insertion.113

Diaphragm use is felt to offer protection against sexually transmitted infections, though studies have varied in reported rates of reduction.117, 118 The utility of diaphragms with or without spermicides and lubricants in preventing HIV transmission has been a recent focus of family planning research.111, 119, 120, 121, 122 While many studies have been promising, the role of vaginal microbicides alone or in conjunction with diaphragm use for reduction of HIV and STI transmission is not settled. More research is needed to explore this potentially significant HIV-reduction strategy.123

The diaphragm offers protection from human papilloma virus, as diaphragm users experience fewer changes in cervical cytology and fewer cases of cervical dysplasia, carcinoma in situ, and cervical cancer.35, 36, 37

An increased incidence of urinary tract infection (UTI) occurs in diaphragm users, compared with users of hormonal methods of contraception.124, 125 It was long believed that the pathogenesis was compression of the distal urethra by the rim of the diaphragm, causing stasis, urinary retention, and ultimately infection. Subsequent studies have shown that a change in the vaginal flora occurs during barrier contraceptive use. The normal vaginal environment, rich in Lactobacillus acidophilus, possesses an acidic pH around 4, except during menstruation, infection, and after semen deposition. Spermicides used with the diaphragm, as with other barrier methods, change the natural vaginal microenvironment, replacing it with a flora rich in anaerobes and E. coli, and making a woman more susceptible to bacteriuria.126 A comparison of sexual intercourse alone with sexual intercourse with a diaphragm and spermicide used in the preceding 3 days was strongly associated with increased rates of vaginal colonization with uropathogenic flora, including E. coli, other Gram-negative uropathogens, group D streptococci, and Candida spp. It was concluded that bacterial and fungal vaginal microflora are strongly influenced by the recent use of a diaphragm and spermicide, and minimally affected by sexual intercourse alone.127

CERVICAL CAP

First described by a German gynecologist in the 1830s, the cervical cap was once a commonly used method of barrier contraception in Western Europe. It was similarly popular in the United States in the 1930s until the diaphragm replaced it in popularity. Cervical cap use further decreased with the invention of oral contraceptives in the 1960s.128

Despite its relative lack of popularity in the US, the cervical cap offers effective reversible contraception free of systemic side effects. It likely also offers some degree of protection against sexually transmitted infection.

 

Types of cervical caps

In the 1900s, multiple types of cervical caps were available. Traditional cervical caps included the Prentif or cavity-rim cap, a rubber device with a thick rim; the Dumas or vault cap, a shallow dome-like latex cap; and the Vimule cap, also a dome-like latex cap, thin at the center and thick at the periphery with a slanted rim. All were composed of latex or silicone, and were intended to fit snugly over the cervix (with the Vimule and Duman extending into the vaginal fornices) (Fig. 3). After 2000, two additional products were introduced: the FemCap® (FemCap, Inc., Del Mar, CA), a silicone cap with an indented bowl for covering the cervix and a strap intended to ease removal; the Oves (Veos Ltd., UK), a disposable silastic device with a thin membrane designed to fit over the cervix. As of today, only the FemCap is available in the United States. An additional product, Lea’s Shield (YAMA, Union, NJ), is a silicone bowl-shaped barrier contraceptive device somewhat different in design from the diaphragm and cervical cap that is also available in the United States.

 

Fig. 3. Mechanical contraceptive devices. (A) Vaginal coil spring diaphragm. (B) Dumas cervical cap. (C) Prentif cervical cap. (D) Vimule cervical cap.

Since patient anatomy and factors such as parity will affect the size of cervical cap required, each type of cervical cap is available in a range of sizes, and require personal fitting. Because they are made of rubber, all traditional caps are sensitive to oily and greasy substances. Spermicide is used with traditional cervical caps; for example, the Prentif cap should be filled approximately one-third full with a spermicidal cream before insertion.

The FemCap, FDA approved in 2003, is a unique barrier device composed of highly elastic silicone rubber (Fig. 4), with a shape aptly described as a sailor hat. It consists of a thin dome to fit and cover the cervix completely, a rim extending into the vaginal fornices, and a brim that conforms to the vaginal walls around the cervix. The border of the dome at its junction with the brim forms a slightly narrower and thicker soft, rounded ring to seal the device to the cervix. The one-piece device is provided with a strap of the same material, located over the dome, to facilitate removal. The FemCap comes in three sizes: small (22 mm), for women who have never been pregnant; medium (26 mm), for women who have been pregnant but have not had a vaginal delivery; and large (30 mm), for women who have had a vaginal delivery. Like other cervical caps, spermicide should be placed prior to insertion (approximately ¾ teaspoon total).129

 

Fig. 4. FemCap is a new cervical cap made of silicone rubber. (A) The FemCap in place. (B) Diagram of FemCap components.

 

 

 

       A                   

 

 

 

 

     B

 

Introduced in 2001, Lea's shield is another barrier contraceptive with a design somewhat between a diaphragm and cervical cap (Fig. 5). This intriguing silicone device is unique because a single size may be used by all women. It consists of a thick bowl-shaped dome with an internal diameter of 30 mm to fit and cover the cervix. The rim of the dome is thickest posteriorly, and the opposite side contains a strong, thick loop to facilitate removal. The loop, placed against the anterior vaginal wall, contributes to its fixation and is accessible to the fitting and removal finger. The dome contains a hole at its apex connecting with a tubular valve running parallel to the dome and the loop. This valve permits the escape of air trapped at insertion and the passage of cervical secretions, thus creating better fit over the cervix. According to manufacturer instructions, Lea's shield should be used with approximately 2 teaspoons of spermicidal gel placed prior to insertion. The device, designed to fit all women, is intended to be sold over-the-counter, but currently it requires a prescription in the United States.17, 129

 

Fig. 5. Lea's shield. (A) Cervical view. (B) Lea's shield in position as far as it can comfortably go. It will settle in place, covering the cervix automatically. The loop is kept frontally and pressed behind the pubis bone. (C) For removal, the loop is held with the index finger and it is then twisted and pulled out. (From: Hunt WL, Gabbay L, Potts M: Lea's shield, a new barrier contraceptive preliminary clinical evaluations, three days' tolerance study. Contraception 50:551, 1994.)


Use of the cervical cap

Conventional cervical caps differ from diaphragms because they are not placed to fit in the vagina but only to shield the cervix. Less elastic than the diaphragm, cervical caps are held in place by suction on the cervix and by the positive abdominal pressure and weight of the abdominal viscera on the vagina. When fitted and placed properly, the cervical cap is somewhat more difficult to place properly and remove than a diaphragm, even when the cap is provided with a removal string. Typical cervical caps are inserted before intercourse and can be worn for up to 48 hours.

Proper use of the cervical cap requires extensive handling of the genitalia, ability to locate the cervix, and manipulation of the device into proper position. In general, cervical caps should not be worn longer than 2 days and not during menstruation. Based on WHO Medical Eligibility Criteria, women who are being treated or initiating treatment for cervical dysplasia or cancer should not use the cervical cap.130 In addition, caution should be exercised in recommending the cap to women with a very short cervix, poor vaginal support, a severely lacerated, inflamed, infected cervix. It is also contraindicated in women with short fingers, a lack of mechanical dexterity, or an aversion to touching their own genitals. Women in the postpartum period or recent second-trimester spontaneous or induced abortion should defer cervical cap use for 6 weeks. Table 7 lists guidelines for the use of cervical caps.

 

Table 7. Use of the cervical cap

 Insertion
 Fill approximately one-third of the cap with spermicidal gel, cream, or foam
 Place the rim of the cap around the cervix until the cervix is completely covered
 Press gently on the dome of the cap to apply suction and seal the cap
 Insert the cap any time up to 42 hours prior to intercourse
 Removal
 Leave the cervical cap in place for at least 6 hours after the last intercourse, but not for more 
than 48 hours from the time it was placed
 Tip the cap rim sideways to break the seal against the cervix, then gently pull the cap downwards
 and out of the vagina

Modified from: World Health Organization Department of Reproductive Health and Research (WHO/RHR) and Johns Hopkins Bloomberg School of Public Health/Center for Communication Programs (CCP), INFO Project. Family Planning: A Global Handbook for Providers. Baltimore and Geneva: CCP and WHO, 2007

 

In using the FemCap, the spermicide should be placed in the space between the outer aspect of the dome and the brim, and a smaller amount should be smeared on the edge and anterior of the dome. The FemCap requires a smaller amount of spermicide than the Prentif cervical cap. It is theorized that as ejaculation occurs, the brim, in close apposition to the vaginal wall, will direct the ejaculate and motile sperm toward the space surrounding the dome where most of the spermicide is located.131 Because the greater volume of spermicide is not in direct contact with the vaginal epithelium, it theoretically could cause less local irritation. The device does not require additional doses of spermicide before repeated intercourse. Silicone rubber is nonallergenic, and the cap may be washed with any soap or detergent.

The association between cervical cap use and cervical dysplasia has been evaluated. A Cochrane Review reported that the Prentif cap had a higher proportion of class I to class II cervical cytologic conversions after 3 months of use when compared to the diaphragm (odds ratio 2.3). However, the same review reported no differences between Papanicolaou findings of FemCap users and diaphragm users.132

 

Effectiveness

Efficacy of the cervical cap in preventing pregnancy is dependent on the design. Two prior randomized controlled trials have been performed. The first compared the traditional Prentif cervical cap to diaphragm, finding that over 2 years of use, pregnancy rates were not statistically different.132 However, a 6-month comparative study between FemCap and a conventional diaphragm showed typical use pregnancy probabilities of 13.5% among FemCap users and 7.9% among diaphragm users (adjusted risk of pregnancy of 1.96).132, 133

Concerning non-contraceptive benefits, Prentif cervical cap users had a lower odds ratio of vaginal ulcerations or lacerations compared to diaphragm users (OR 0.3). FemCap users had a lower odds ratio of urinary tract infections compared to diaphragm users (OR 0.6).132

Evaluation of Lea's Shield demonstrated acceptability, safety, and contraceptive efficacy. One study randomized women to Lea's Shield use with and without spermicide. Adjusted pregnancy rates were 5.6 per 100 women in spermicide users, compared with 9.3 per 100 in non-spermicide users, with a trend toward significance (p = 0.086). Unadjusted rates were similar between groups.134

The cervix is recognized as an important site of entry for HIV during intercourse,135 and cervical caps may provide protection against HIV and other STDs. In addition, the newer FemCap and Lea's Shield offer the potential for improved protection.96

 

VAGINAL CONTRACEPTIVE INSERTS

Vaginal contraceptive inserts, most commonly in the form of films or suppositories, are intended for use either alone or with a barrier contraceptive. Both films and suppositories require adequate time to dissolve within the vagina prior to initiation of intercourse (usually 10–15 minutes).

Available contraceptive inserts in the United States contain N-9 as spermicide, and include brands names such as Encare (contains 100 mg N-9; manufactured by Blairex Laboratories, Columbus, IN). The vaginal contraceptive film (VCF) is also available (contains 70 mg N-9; manufactured by Apothecus Pharmaceutical Corp, Oyster Bay, NY). A randomized trial of VCF versus placebo film concluded that VCF did not offer added protection against HIV, gonorrhea, and chlamydia over condoms alone.136

 

CONTRACEPTIVE SPONGE

Perhaps the oldest mechanical intravaginal device used for contraception is the vaginal sponge and its variations. Wads of cloth, cotton tufts, sea sponges, powder puffs, and the like have been used throughout history and are still in use all over the world, either alone or in combination with different solutions, presumably spermicides. The sponge combines mechanical and chemical barriers to sperm. The vaginal sponge provides some advantages over the diaphragm and the cervical cap, although not as much contraceptive protection as the diaphragm. It is self-administered and does not require a pelvic examination or fitting; one size fits all. It has no contraindications, except for persons allergic to the sponge material or the spermicide or persons averse to touching their genitals. Available without prescription, the vaginal sponge can be personally procured, inserted, and removed. It can be used as a back-up method for the condom. There is no waiting period after insertion to be effective. It can be inserted hours before a sexual encounter, avoiding a potentially messy interruption of sexual activity, while upholding confidentiality. The user may engage in repeated coitus without the need for additional preparation.137 Sponges may offer protection against some STDs. Sponges are an appealing and effective option under a woman's control that do not require professional intervention.

The disposable Today sponge was introduced to the US market in 1983. It was withdrawn from the market in 1995 due to FDA compliance issues, as the manufacturer chose to discontinue production rather than change design. In 2005, Today (Mayer Laboratories, Berkley, CA) was reintroduced to the market after FDA clearance. The single-use sponge consists of a molded hydrophilic polyurethane soft foam impregnated with 1 gram of N-9. An indentation on one side allows the sponge to fit against the cervix, and the other side contains a ribbon to facilitate removal. The sponge should be wet with tap water and squeezed prior to insertion.17

Offered in Europe and Canada, Protectaid is a polyurethane sponge containing low concentrations of three spermicides: benzalkonium chloride, sodium cholate, and N-9.138, 139 The Protectaid sponge is pre-moistened in the package; it is not necessary to apply water.

A Cochrane review comparing the sponge with the diaphragm found the sponge significantly less effective at preventing pregnancy. In addition, discontinuation rates were higher with the sponge.140 Effectiveness varies between nulliparous and parous women. First-year unintended pregnancy rates for perfect and typical use are 9% and 16%, respectively, in nulliparous users, compared with 20% and 32% in their parous counterparts.2

Some studies have suggested possible protection from gonorrhoea, chlamydia, and trichomonas acquisition in sponge users,141, 142 though data are limited. A study of commercial sex workers in Nairobi found that the sponge with N-9 did not offer protection against HIV infection.143 The sponge contributed to vaginal dryness, and the seroconversion was credited to an increase in vaginal sores that facilitated viral infection. Women in this study had multiple coital episodes with the sponge; the situation may be quite different in other clinical scenarios. Frequent use of N-9 has been linked to vaginal irritation and mucosal abrasions, which were dose-dependent.144 There have been cases of TSS temporally associated with use of the contraceptive sponge. The risk was mostly related to its use during menstruation and the puerperium and prolonged retention of the device.145

 

SPERMICIDES

Substances for vaginal application formulated to prevent conception have been in use since pharaonic times and form part of the folklore of most cultures. From the time of their discovery, spermatozoa were found to be killed by many substances. Formal experimentation with chemical inhibiters of sperm began in the 1800s.146 By the 1950s, different vaginal creams, pastes, suppositories, and other vaginal inserts of uncertain quality, suspicious origin, and questionable effectiveness were being marketed. However, with time, these chemical contraceptives became more regulated, with requirements for their safety and effectiveness.

Globally, due the extent of the HIV epidemic, much research focuses on vaginally administered agents protective against STD transmission. Increasing knowledge of the ecology of the human vagina provides basic knowledge related to the problems encountered in the general use of existing spermicides. Considerable research effort is being made by the private and public sector with the goal of finding products with strong bactericidal and viricidal activity, in addition to spermicidal activity, that will not affect the vaginal and cervical epithelia and will preserve vaginal mucosa integrity. Numerous products are at different stages of testing. The pharmaceutical industry seems at times to have remained uninterested in this quest since the market for preparations of this kind will be mostly for populations with meager acquisitive power.

Spermicides are agents that kill spermatozoa or render them incapable or normal function. Microbicides are self-administered prophylactic agents used to prevent transmission of sexually transmitted pathogens, with HIV being the most significant today. In the broadest terms, microbicides may be given through any route or mode of administration, but most current research centers on vaginally-administered, female-controlled products. Given these definitions, there is a basis for overlap between spermicidal and microbicidal agents. The most widely used spermicides—such as N-9, octoxynol-9, and menfegol—are surfactant agents, which disrupt cell membranes and kill bacteria, parasites, and most viruses in vitro.147 Other common compounds have shown spermicidal activity (e.g. benzalkonium chloride, chlorhexidine, gramicidin, cholate, and betadine).

 

Types of spermicides

An ample array of pharmaceutical methods have been and are still used to deliver spermicides into the vagina. There are traditional forms, such as vaginal jellies and creams, suppositories, and effervescent tablets, with many improvements since their inception. There are newer forms, such as foams, and more recently, the vaginal contraceptive film (Table 8).

 

Table 8. Brand name spermicide products available in the United States

 Gels, jellies, and creams
  Advantage 24 Gel
  Conceptrol Gel
  Gynol II Extra Strength Jelly
  KY Plus Jelly
  Ramses Crystal Clear Gel
  Shur-Seal Gel
  Film
  Vaginal Contraceptive Film
 Foams
 Delfen Foam
 Emko
 Suppositories/Inserts
 Encare

Modified from: Spermicides (Vaginal Route). Available from:

http://www.mayoclinic.org/drugs-supplements/spermicide-vaginal-route/description/drg-20070769 Accessed Jan 2016

 

Use of spermicide products

Vaginal spermicides are inserted before coitus. Jellies, creams, foams may be inserted immediately before sex; suppositories, films, and effervescent tablets must be inserted a few minutes (up to 30 minutes) before intercourse to allow for melting, dissolving, and dispersion. A new dose should be inserted if coitus does not take place within 1 hour from the initial application. A new dose is required before each coital event. The time element, the need for repeated doses, and the handling of the genitals at each event may disrupt spontaneity and constitute an inhibiting nuisance for some potential users. As the vagina cleans itself by discharging its contents onto the perineum, the use of spermicides involves some messiness when part of the contraceptive and the ejaculate efflux from the vagina postcoitally. Douching is not recommended but if desired should not be performed until 2 hours after vaginal coitus.

Spermicides require a number of immediate precoital maneuvers and handling of the genital organs, which is not acceptable to some potential users. All conspire for misuse and frequent discontinuation. All have a number of disadvantages that limit their acceptability. When used alone, they offer limited contraceptive protection. The reported range of failure rates is vast, with studies showing less than 5% to over 50% in the first year of use. The largest trial to date showed that contraceptive efficacy was dose dependent, with a 52.5 mg dose of nonoxynol-9 associated with a 22% risk of pregnancy by 6 months.147

Table 9 lists the indications and contraindications for topical spermicides. In practice, vaginal spermicides are recommended as an occasional or provisional method prior to IUD insertion or initiation of hormonal contraception, or for the unexpected sexual encounter.

Spermicides are used mostly in combination with mechanical methods (e.g. condoms, diaphragms, and cervical caps), as lubricants, adjuvants in case of condom rupture, and secondary protection against STDs and HIV, although patients must be educated that commercially available spermicide products likely offer no additional protection against infection.148 Also, women desiring to use spermicides alone should be made aware that unintended conceptions are more the rule than the exception. Spermicides are not intended for postcoital use and are not substitutes for hormonal emergency contraception (oral levonorgestrel or combined levonorgestrel-ethinyl estradiol).

 

Table 9. Indications and contraindications for spermicide use

Indications
Adjuvant to mechanical contraceptives: diaphragm, cervical cap, condoms
Adjuvant to rhythm, calendar, or periodic abstinence contraceptive methods
Temporary use, at initiation of certain hormonal contraceptive methods
Increase in vaginal lubrication desired
Contraindications
Absolute Relative Temporary
Need for contraceptive method of greater effectivenessHistory of failed use of spermicidesActive or suspected STD until treated or condition clarified
HIV infection

Dyspareunia

Acute or subacute vaginitis

Allergy or sensitivity to ingredients in product by either partnerVaginismus

Urethritis

Chronic genital dermatitis, eczema genitalis, genital psoriasis, other chronic genital dermatosis 

Cystitis

 

Modified from: Sobrero AJ, Sciarra JJ. Contraception. In Cohn HF (ed): Current Therapy. Baltimore, WB Saunders Company, 1978

 

The practical value of vaginal spermicides is their wide availability. They are sold without prescription, which makes them accessible to a large population unwilling or unable to seek professional advice and examination. They are simple to use, relatively inexpensive, and are under a woman's control. Although currently available spermicides have little to any role in preventing STIs and HIV, especially if used alone, new preparations or vaginal spermicides in conjunction with barrier methods may offer some protection against some STDs.149, 150 Investigations into a new microbicides are showing promising results, though continued investigation is necessary, including into potential spermicidal properties.111, 151

In general, spermicidal products are bulky and conspicuous. The recommended dose varies according to the physical characteristics of the product. Film, suppositories, and foaming tablets are dispensed in units for direct use. Foams, jellies, and creams are provided with a syringe inserter containing the recommended amount. Most users' complaints are of excessive lubrication, leakage and messiness after intercourse, local irritation and pruritus, and occasional allergy to the active ingredient or the vehicle. Jellies provide greater lubrication than creams but in general are aesthetically less acceptable because of excess leakage after coitus. Creams and foams are slightly 'drier' and perceived as less messy. The dosage of jellies and creams is approximately 5 mL, which is the capacity of the plastic applicator syringe with which these products are usually marketed. It is believed that the bulk of the vehicle in jellies and creams contributes as a partial mechanical barrier. Foams consist of a fluid base in which the spermicide is dissolved; they are packed in a pressurized container with a gas as propellant. The material is released as a foam in volumes of 7–10 mL. They adhere and distribute better in the vagina than do other products. Because the water in creams and jellies is substituted in foams by the propellant gas, foams tend to be less messy, leak less often, and aesthetically are more acceptable. Most spermicides have an excellent shelf-life when stored properly at room temperature. They should not be refrigerated and never frozen.

In the early 1980s, significant concern arose about pregnancy outcomes with spermicide exposure. Multiple studies concerning use of spermicides prior to conception or at the time of conception have been performed, investigating increased risks of miscarriage, chromosomal abnormalities, and birth defects.152, 153, 154, 155, 156, 157 Overwhelmingly, the data does not support an association between spermicides and poor obstetric outcomes, and no additional precautions are recommended.158, 159

 

Nonoxynol-9

Nonoxylol-9 (N-9) remains the most widely available spermicide on the market. In the 1970–1980s, laboratory studies suggested that N-9 may inactivate many sexually transmitted pathogens, including Neisseria gonorrhoea, Chlamydia trachomatis, and even HIV.160 However, subsequent clinical trials have not supported the initial laboratory findings. Multiple comprehensive reviews of available literature suggest that in fact nonoxynol-9 does not protect against sexually transmitted infections, leading to the WHO’s recommendation that N-9 should not be recommended for general STI prevention.148, 160, 161 In fact, studies have linked nonoxynol-9 to increased rates of HIV infection, especially in high risk populations.162, 163 This is likely secondary to N-9 causing genital irritation and disruption of the vaginal epithelium which makes a woman more susceptible to transmission.160, 161, 163 Starting in 2007, the FDA required all over-the-counter vaginal contraceptives containing N-9 to carry a warning statement that N-9 products do not protect against HIV or other STIs, and may increase the risk of contracting HIV from an infected partner.164

 

As far as pregnancy prevention, WHO continues to support the use of N-9 alone in populations at low-risk for STIs/HIV, noting that N-9 formulations continue to reduce the risk of pregnancy compared to no product.148

 

THE FUTURE: DUAL PROTECTION

Many of our methods have attempted to find a balance between effective contraception and infectious protection, at times improving one at the expense of the other. Effective dual-protection methods, providing both contraception and protection against STIs and HIV, are increasingly becoming a focus of research and development. Ideally, new methods are female-controlled, easy to use, and accessible to a wide variety of populations.

Multiple vaginal microbicides are currently under investigation, with many shown to be safe and acceptable. Multiple effectiveness trials are underway, with some formulations showing promising results.151, 165 While many of these are focusing on microbicidal activity alone, some have also looked at spermicidal properties, again with promising results.111

If the advancements in contraceptive technology over the past 100 years are a predictor of what is to come, we will continue to move closer to the goal of modern family planning: provision of an effective contraceptive that also maximizes non-contraceptive benefits and lifestyle advantages. Undoubtedly, barrier methods will continue to play a role in realizing this goal.

REFERENCES

1

Sedgh G, Singh S, Hussain R: Intended and unintended pregnancies worldwide in 2012 and recent trends. Stud Fam Plann. 2014 Sep;45(3):301-14. PMID 25207494

2

Trussell J. Choosing a Contraceptive: Efficacy, Safety, and Personal Considerations. In: Hatcher R, ed. Contraceptive Technology, 19th ed. New York: Ardent Media;2008:19-47.

3

Gavin L, Moskosky S, Carter M, et al: Providing quality family planning services: Recommendations of CDC and the U.S. Office of Population Affairs. MMWR Recomm Rep. 2014 Apr 25;63(RR-04):1-54. PMID 24759690

4

Heymann, D (ed): Control of Communicable Diseases Manual, 20th ed. Washington DC, American Public Health Association Press: 2015.

5

Higgins J, Hoffman S, Dworkin S: Rethinking Gender, Heterosexual Men, and Women’s Vulnerability to HIV/AIDS. Am J Public Health. 2010 March:100(3):435-445. PMC: 2820057

6

Satterwhite C, Torrone E, Meites E, et al: Sexually transmitted infections among US women and men: prevalence and incidence estimates, 2008. Sex Transm Dis. 2013 Mar;40(3):187-93.

7

World Health Organization: Sexually transmitted infections (STIs) Fact Sheet. 2015 Dec. Retrieved from: http://www.who.int/mediacentre/factsheets/fs110/en/

8

Chun H, Carpenter R, Macalino G, et al: The Role of Sexually Transmitted Infections in HIV-1 Progression: A Comprehensive Review of the Literature. J Sex Transm Dis. 2013;2013:176459 PMCID 4437436

9

Sexton J, Garnett G, Rottingen J: Metaanalysis and metaregression in interpreting study variability in the impact of sexually transmitted diseases on susceptibility to HIV infection. Sex Transm Dis. 2015 Jun;32(6):351-7. PMID 15912081

10

Johnson L, Lewis D: The Effect of Genital Tract Infections on HIV-1 Shedding in the Genital Tract: A Systematic Review and Meta-Analysis. Sex Transm Dis. 2008 Nov;35(11):946-59. PMID 18685546

11

World Health Organization: HIV/AIDS Fact Sheet. 2015 Nov. Retrieved from: http://www.who.int/mediacentre/factsheets/fs360/en/

12

Friend D: An update on multipurpose prevention technologies for the prevention of HIV transmission and pregnancy. Expert Opin Drug Deliv. 2016 Jan;22:1-13. PMID 26742698

13

Berer M: Dual protection: more needed than practiced or understood. Reprod Health Matters. 2006 Nov;14(28):162-70. PMID 17101435

14

Benagiano G, Carrara S, Filippi V, et al: Condoms, HIV and the Roman Catholic Church. Reprod Biomed Online. 2011 Jun:22(7):701-9. PMID21507723

15

ESHRI Capri Workshop Group: Simultaneous prevention of unintended pregnancy and STIs: a challenging compromise. Hum Reprod Update. 2014 Nov-Dec;20(6):952-63. PMID 24935861

16

Holmes KK, Levine R, Weaver M: Effectiveness of condoms in preventing sexually transmitted infections. Bull World Health Organ. 2004 Jun;82(6):454-61

17

Cates W, Raymond E: Vaginal Barriers and Spermicides. In: Hatcher R, ed. Contraceptive Technology. 19th edn. New York: Ardent Media; 2008:317-335

18

Peipert JF, Lapane KL, Allsworth JE, et al: Women at risk for sexually transmitted diseases: correlates of intercourse without barrier contraception. Am J Obstet Gynecol. 2007 Nov;197(5):474.e1-8. PMID 17714677

19

Trussell J: Contraceptive failure in the United States. Contraception. 2011 May;83(5):397-404. PMID 21477680.

20

Hearst N, Chen S: Condom promotion for AIDS prevention in the developing world: is it working? Stud Fam Plann. 2004 Mar;35(1):39-47. PMID 15067787.

21

Himes NE: Medical History of Contraception. Baltimore, Williams &Wilkins, 1936

22

Giannou FK, Tsiara CG, Nikolopoulos GK, et al: Condom effectiveness in reducing heterosexual HIV transmission: a systematic review and meta-analysis of studies on HIV serodiscordant couples. Expert Rev Parmacoecon Outcomes Res. 2015 Oct;21:1-11. PMID 26488070

23

Weller S, Davis K: Condom effectiveness in reducing heterosexual HIV transmission. Cochrane Database Syst Rev. 2002;(1):CD003255. PMID 11869658

24

McNaught J, Jamieson MA: Barrier and spermicidal contraceptives in adolescence. Adolesc Med Clin. 2005 Oct;16(3):495-515. PMID 16183536

25

Trussell J: Contraceptive Efficacy. In: Hatcher R, ed. Contraceptive Technology. 19th edn. New York: Ardent Media; 2008:747-825

26

Chandra A, Martinez GM, Mosher WD et al: Fertility, family planning, and reproductive health of U.S. women: data from the 2002 National Survey of Family Growth. Vital Health Stat 23. 2005 Dec;(25):1-160. PMID 16532609

27

Scott A, Glasier A: Evidence based contraceptive choices. Best Pract Res Clin Obstet Gynaecol. 2006 Oct;20(5):665-80. PMID16707277

28

Warner L, Stone KM, Macaluso M et al: Condom use and risk of gonorrhea and Chlamydia: a systematic review of design and measurement factors assessed in epidemiologic studies. Sex Transm Dis. 2006 Jan;33(1):36-51

29

Warner L, Macaluso M, Austin HD et al: Application of the case-crossover design to reduce unmeasured confounding in studies of condom effectiveness. Am J Epidemiol. 2005 Apr 15;161(8):765-73

30

Koss CA, Dunne EF, Warner L: A systematic review of epidemiologic studies assess condom use and risk of syphilis. Sex Transm Dis. 2009 Jul;26(7):401-405. PMID 19455075

31

Steiner MJ, Cates W: Are condoms the answer to rising rates of non-HIV sexually transmitted infections? Yes. BMJ. 2008 Jan 26;336(7637):184

32

Kellaham J, Rubin FL, Ory HW et al: Barrier contraceptive methods and pelvic inflammatory disease. JAMA. 1982 Jul 9;248(2)184-7. PMID 7087109

33

Cates Jr WC: Contraceptive choice, sexually transmitted diseases, HIV infection and future fecundity. J Br Fertil Soc. 1996;1(1):18-22. PMID 12346972

34

Brunham RC, Gottlieb SL, Paavonen J: Pelvic Inflammatory Disease. N Engl J Med. 2015 May 21;372(21):2039-48. PMID 25992748.

35

Parazzini P, Negri E, La Vecchia C et al: Barrier methods of contraception and the risk of cervical neoplasia. Contraception 1989 Nov;40(5):519-30. PMID 2692961

36

Coker AL, Hulka BS, McCann MF, et al: Barrier methods of contraception and cervical intraepithelial neoplasia. Contraception. 1992 Jan;45(1):1-10

37

Kost K, Forrest JD, Harlap S: Comparing the health risks and benefits of contraceptive choices. Fam Plann Perspect. 1991 Mar-Apr;23(2):54-61. PMID 2060612.

38

Schwartz B, Gaventa S, Broome CV, et al: Nonmenstrual toxic shock syndrome associated with barrier contraceptives: report of a case-control study. Rev Infect Dis. 1989 Jan-Feb;11. PMID 2928652

39

DeVries AS, Lesher L, Schlievert PM, et al: Staphylococcal toxic shock syndrome 2000-2006: epidemiology, clinical features, and molecular characteristics. PLoS One. 2011;6(8):e22997. PMID 21860665

40

Grady WR, Klepinger DH, Nelson-Wally A: Contraceptive characteristics: the perceptions and priorities of men and women. Fam Plann Perspect. 1999 Jul-Aug;31(4):168-75. PMID 10435215

41

Li D, Wilcox AJ, Dunson DB: Benchmark pregnancy rates and the assessment of post-coital contraceptives: an update. Contraception. 2015 Apr;91(4):344-9. PMID 25592079

42

Beckman LJ, Harvey SM: Factors affecting the consistent use of barrier methods of contraception. Obstet Gynecol. 1996 Sep;88(3 Suppl):65S-71S. PMID 8752230.

43

El-Ibiary SY, Youmans SL: Health literacy and contraception: a readability evaluation of contraceptive instructions for condoms, spermicides and emergency contraception in the USA. Eur J Contracept Reprod Health Care. 2007 Mar;12(1):58-62. PMID 17455046

44

Yee YM, Simon MA: The role of health literacy and numeracy in contraceptive decision-making for urban Chicago women. J Community Health. 2014 Apr;39(2):394-9. PMID 24105614

45

Rutherford J, Holman R, MacDonald J et al: Low literacy: a hidden problem in family planning clinics. J Fam Plann Reprod Health Care. 2006 Oct;32(4):235-40. PMID 17032511

46

Peipert JF, Redding CA, Blume JD et al. Tailored intervention to increase dual-contraceptive method use: a randomized trial to reduce unintended pregnancies and sexually transmitted infections. Am J Obstet Gynecol. 2008 Jun;198(6):630.e1-8. PMID18395692

47

Morrison CS, Cates W Jr: Preventing unintended pregnancy and HIV transmission: dual protection or dual dilemma? Sex Transm Dis. 2007 Nov;34(11):873-5. PMID 18049423

48

Raine T, Minnis AM, Padian NS: Determinants of contraceptive method among young women at risk for unintended pregnancy and sexually transmitted infections. Contraception. 2003 Jul;68(1):19-25. PMID 12878282.

49

Khan F, Mukhtar S, Dickinson IK, et al: The story of the condom. Indian J Urol. 2013 Jan-Mar;29(1):12-15. PMID 23671357

50

Shih SL, Kebodeaux CA, Secura GM, et al: Baseline correlates of inconsistent and incorrect condom use among sexually active women in the contraceptive CHOICE Project. Sex Transm Dis. 2011 Nov;38(11):1012-9. PMID 21992976

51

Blake SM, Ledsky R, Goodenow C et al: Condom availability programs in Massachusetts high schools: relationships with condom use and sexual behavior. Am J Public Health. 2003 Jun;93(6):955-62. PMID 12773362

52

Sandoy IF, Blystad A, Shayo EH, et al: Condom availability in high risk places and condom use: a study at district level in Kenya, Tanzania and Zambia. BMC Public Health. 2012 Nov 26;12:1030. PMID 23181969

53

Levy DA, Khouader S, Leynadier F: Allergy to latex condoms. Allergy. 1998 Nov;53(11):1107-8. PMID 9860250

54

Hamilton E: Itching and rashes on contact with latex among patients attending community contraceptive clinics. J Fam Plann Reprod Health Care. 2008 Apr;34(2):129-30. PMID 18413032

55

Mayer DP: Talc and condoms. JAMA. 1995 Oct 25;274(16):1269-70. PMID 7563529

56

Kasper CS, Chandler PJ Jr: Possible morbidity in women from talc on condoms. JAMA. 1995 Mar 15;273(11):846-7. PMID 7869551

57

East L, Jackson D, O’Brien L, et al: Use of the male condom by heterosexual adolescents and young people: literature review. J Adv Nurs. 2007 Jul;59(2):103-10

58

Albert AE, Hatcher RA, Graves W: Condom use and breakage among women in a municipal family planning clinic. Contraception 45: 429, 1991. PMID 2040169

59

Sparrow MJ, Lavill E: Breakage and slippage of condoms in family planning clients. Contraception 50: 117, 1994. PMID 7956211

60

D’Anna LH, Korosteleva O, Warner L, et al: Factors associated with condom use problems during vaginal sex with main and non-main partners. Sex Transm Dis. 2012 Sep;39(9):687-93. PMID 22895490

61

Duerr A, Gallo MF, Warner L, et al: Assessing male condom failure and incorrect use. Sex Trasm Dis. 2011 Jul;38(7):580-6. PMID 21278626

62

Cates W: The NIH condom report: the glass is 90% full. Fam Plann Perspect. 2001 Sept-Oct;33(5):231-3. PMID 11589545

63

World Health Organization: Male Latex Condom: Specification, Prequalification and Guidelines or Procurement, 2010. Geneva: WHO Press; 2010(revised 2013 April):1-152

64

Steiner M, Foldesy R, Cole D et al: Study to determine the correlation between condom breakage in human use and laboratory test results. Contraception. 1992 Sep;46(3):279-88. PMID 1451523

65

Free MJ, Srisamang V, Vail J et al: Latex rubber condoms: Predicting and extending shelf life. Contraception 53: 221, 1996. PMID 8706440

66

Crosby R, Graham C, Milhausen R et al: Associations between rushed condom application and condom use errors and problems. Sex Transm Infect. 2015 Jun;91(4):275-7. PMID25391833

67

Carey RF, Herman WA, Retta SM et al: Effectiveness of latex condoms as a barrier to human immunodeficiency virus-sized particles under conditions of simulated use. Sex Transm Dis. 1992 Jul-Aug;19(2):230-4. PMID 1411838

68

O’Sullivan LF, Udell W, Montrose VA et al: A cognitive analysis of college students’ explanations for engaging in unprotected sexual intercourse. Arch Sex Behav. 2010 Oct;39(5):1121-31. PMID 19365717

69

Sangi-Haghpeykar H, Horth F, Poindexter AN: Condom use among sterilized and nonsterilized Hispanic women. Sex Transm Dis. 2001 Sep;28(9):546-51. PMID 11518874

70

Emmanuel W, Edward N, Moses P et al: Condom Use Determinants and Practices Among People Living with IHV in Kisii County, Kenya. Open AIDS J. 2015 Nov 13;9:104-11. PMID 26668671

71

Longmire-Avital B, Oberle V: “Condoms are the standard, right?”: Exploratory study of the reasons for using condoms by Black American emerging adult women. Women Health. 2015 Sep 1:1-16. PMID 26327468

72

Andrews CH, Faxelid E, Sychaerun V: Determinants of consistent condom use among female sex workers in Savannakhet, Lao PDR.

73

Spermicide condoms linked to latex allergy. AIDS Alert. 1996 Sep;11(9):107-8. PMID 11363727

74

Chen FC, Buscher U, Niggemann B: Condoms are not a risk factor for sensitization to latex. Contraception. 2002 Dec;66(6):439-41

75

Turjanmaa K, Reunala T: Condoms as a source of latex allergen and cause of contact urticaria. Contact Dermatitis. 1989 May;20(5):360-4. PMID 2766703

76

Levy DA, Moudiki P, Leynadier F: Deproteinised latex condoms are well tolerated by latex allergic patients. Sex Transm Infect. 2001 Jun;77(3):202-3. PMID 11402230

77

Gallo MF, Grimes DA, Lopez LM et al: Non-latex versus latex male condoms for contraception. Cochrane Database Syst Rev. 2006 Jan 25;(1):CD003550. PMID 16437459

78

Gilmore C. The development of non-latex condoms. In: McNeill ET GC, Finger WR, Lewis JH, Schellstede WP, ed. The latex condom: recent advances, future directions. Research Triangle Park: Family Health International; 1998:65-71

79

Trussell J, Warner DL, Hatcher RA: Condom performance during vaginal intercourse: Comparison of Trojan-Enz and Tactylon Condoms. Contraception 45: 11, 1992. PMID 1591918

80

Walsh TL, Frezieres RG, Peacock K et al: Evaluation of the efficacy of a polyurethane condom: results from a randomized controlled clinical trial. Perspect Sex Reprod Health. 2003 Mar-Apr;35(2):79-86. PMID 12729137

81

Cook L, Nanda K, Taylor D: Randomized crossover trial comparing the eZon plastic condom and a latex condom. Contraception. 2001 Jan;63(1):25-31. PMID 11257245

82

Billow JA: Choosing condoms. Am Pharm. 1992 Sep;NS32(9):55-8. PMID 1442556

83

Hughes LM, Griffith R, Aitken RJ: The search for a topical dual action spermicide/microbicide. Curr Med Chem. 2007;14(7):775-86. PMID 17346162

84

Iyer V, Poddar SS: Update on nonoxynol-9 as vaginal spermicide. Eur J Contracept Repord Health Care. 2008 Dec;13(4):339-50. PMID 19117251

85

World Health Organization: WHO/CONRAD technical consultation on nonoxynol-9, World Health Organization, Geneva, 9-10 October 2001: summary report. Reprod Health Matters. 2002 Nov;10(20):175-81. PMID 12569895

86

Handley MA, Reingold AL, Shiboski S et al: Incidence of acute urinary tract infection in young women and use of male condoms with and without nonoxynol-9 spermicides. Epidemiology. 2002 Jul;13(4):431-6. PMID 12094098

87

Foxman B, Marsh J, Gillespie B et al: Condom use and first-time urinary tract infection. Epidemiology. 1997 Nov;8(6):637-41. PMID 9345662

88

Kost K, Singh S, Vaughan B et al: Estimates of contraceptive failure from the 2002 National Survey of Family Growth. Contraception. 2008 Jan;77(1):10-21. PMID 18082661

89

Caucus on New and Underused Reproductive Health Technologies. Product Brief: Female condom. Reproductive Health Supplies Coalition, Brussels, Belgium. Retrieved from: http://www.path.org/publications/files/RHSC_fem_condom_br.pdf

90

Beksinska M, Greener R, Kleinschmidt I et al: A randomized noninferiority crossover controlled trial of the functional performance and safety of new female condoms: an evaluation of the Velvet, Cupid2, and FC2. Contraception. 2015 Sep;92(3):261-7. PMID 26002805

91

Beksinska M, Smit J, Joanis C, et al: Female condom technology: new products and regulatory issues. Contraception. 2011 Apr;83(4):316-21. PMID 21397088

92

Mathenjwa T, Maharaj P: ‘Female condoms give women greater control’: a qualitative assessment of the experiences of commercial sex workers in Swaziland. Eur J Contracept Reprod Health Care. 2012 Oct;17(5):383-92. PMID 22839696

93

Office of Population Affairs: Female Condom: The Facts. U.S. Department of Health & Human Services. 2014 Aug. Retrieved from: http://www.hhs.gov/opa/pdfs/female-condom-fact-sheet.pdf

94

Sakondhabat C: The female condom. Am J Public Health 80: 498, 1990. PMID 2316778

95

Dowdy DW, Sweat MD, Holtgrave DR: Country-wide distribution of the nitrile female condom (FC2) in Brazil and South Africa: a cost-effectiveness analysis. AIDS. 2006 Oct 24;20(16):2091-8. PMID 17053355

96

Minnis AM, Padian NS: Effectiveness of female controlled barrier methods in preventing sexually transmitted infections and HIV: current evidence and future research directions. Sex Transm Infect. 2005 Jun;81(3):193-200. PMID 15923284

97

Potter B, Gerofi J, Pope M et al: Structural integrity of the polyurethane female condom after multiple cycles of disinfection, washing, drying and relubrication. Contraception. 2003 Jan;67(1):65-72. PMID 12521661

98

Beksinska ME, Rees HV, Dickson-Tetteh KE et al: Structural integrity of the female condom after multiple uses, washing, drying, and re-lubrication. Contraception. 2001 Jan;63(1):33-6. PMID 11257246

99

World Health Organization: The Safety and Feasilibity of Female Condom Reuse: Report of a WHO Consultation. WHO. 2002 Jan:1-15

100

World Health Organization: WHO Information Update: Considerations regarding Reuse of the Female Condom. WHO. 2002 Jul:1-4

101

Farr G, Gabelnick H, Sturgen K et al: Contraceptive efficacy and acceptability of the female condom. Am J Public Health. 1994 Dec;84(12):1960-4. PMID 7998637

102

Trussell J, Sturgen K, Strickler J et al: Comparative contraceptive efficacy of the female condom and other barrier methods. Fam Plann Perspect. 1994 Mar-Apr;26(2):66-72. PMID 8033980

103

Peters A, van Driel F, Jansen W: Acceptability of the female condom by sub-Saharan African women: a literature review. Afr J Reprod Health. 2014 Dec;18(4):34-44. PMID 25854091

104

Wang Y, Liao S, Jiang J et al: Who are the preferential targets for intervention programs related to the female condom among sex workers in southern China? AIDS Educ Prev. 2013 Aug;25(4):349-61. PMID 23837812

105

Witte SS, Stefano K, Hawkins C: Can Medicaid reimbursement help give female condoms a second chance in the United States? Am J Public Health. 2010 Oct;100(10):1835-40. PMID 20724690

106

Allen RE: Diaphragm fitting. Am Fam Physician. 2004 Jan 1;69(1):97-100. PMID 14727824

107

Schwartz JL, Ballagh SA, Creinin MD et al: SILCS diaphgragm: postcoital testing of a new single-size contraceptive device. Contraception. 2008 Sep;78(3):237-44. PMID 18692615

108

Coffey PS, Kilbourne-Brook M, Beksinska M et al: Short-term acceptability of a single-size diaphragm among couples in South Africa and Thailand. J Fam Plann Reprod Health Care. 2008 Oct;34(4):233-6. PMID 18854068

109

Schwartz JL, Weiner DH, Lai JJ et al: Contraceptive efficacy, safety, fit, and acceptability of a single-size diaphragm developed with end-user input. Obstet Gynecol. 2015 Apr;125(4):895-903. PMID 25751199

110

Hudson C, Larkin A, Kessel M et al: Single-size Caya® contoured diaphragm is the first new diaphragm design to enter the US market in over 50 years. Seattle, PATH Press Release. 2015 Jun 25.

111

Bayer LL, Jensen JT: ACIDFORM: a review of the evidence. Contraception. 2014 Jul;90(1):11-8. PMID 24565736

112

Ferreira AE, Araújo MJ, Regina CH, Diniz SG, Faúndes A. Effectiveness of the diaphragm, used continuously, without spermicide. Contraception. 1993 Jul;48(1):29-35. PMID 8403903

113

Smith C, Farr G, Feldblum PJ et al: Effectiveness of the non-spermicidal fit-free diaphragm. Contraception. 1995 May;51(5):289-91. PMID 7628202

114

Alcid DV, Kothari N, Quinn EP et al: Toxic shock syndrome associated with diaphragm use for only nine hours. Lancet 1: 1363, 1983. PMID 6123670

115

Davis JP, Chesney Wand PJ, Laventure M: Toxic shock syndrome: Epidemiologic features, recurrence, risk factors and prevention. N Engl J Med 303: 1429, 1980. PMID 7432401

116

Vessey M, Lawless M, Yeates D: Efficacy of different contraceptive methods. Lancet. 1982 Apr 10;1(8276):841-2. PMID 6122067

117

Cates W, Stone KM: Family planning, sexually transmitted disease and contraceptive choice: a literature update—Part 1. Fam Plann Perspect. 1992 Mar-Apr;24(2):75-84. PMID 1612146

118

d’Oro LC, Parazzini F, Naldi L et al: Barrier methods of contraception, spermicides, and sexually transmitted diseases: a review. Genitourin Med. 1994 Dec;70(6)410-7. PMID 7705860

119

Guest G, Johnson L, Burke H et al: Changes in sexual behavior during a safety and feasibility trial of amicrobicide/diaphragm combination: an integrated qualitative and quantitative analysis. AIDS Educ Prev. 2007 Aug;19(4):310-20. PMID 17685844

120

Padian NS, van der Straten A, Ramjee G et al: Diaphragm and lubricant gel for prevention of HIV acquisition in southern African women: a randomised controlled trial. Lancet. 2007 Jul 21;370(9583):251-61. PMID 17631387

121

Thorburn S, Harvey SM, Tipton J: Diaphragm acceptability among young women at risk for HIV. Women Health. 2006;44(1):21-39. PMID 17182525

122

Montgomery ET, Cheng H, van der Straten A et al: Acceptability and use of the diaphragm and Replens lubricant gel for HIV prevention in Southern Africa. AIDS Behav. 2010 Jun;14(3):629-38. PMID 19757018

123

Harvey SM, Branch MR, Thorburn S et al: Exploring diaphragm use as a potential HIV prevention strategy among women in the United States at risk. AIDS Educ Prev. 2008 Apr;20(2):135-47. PMID 18433319

124

Vessey MP, Metcalfe MA, McPherson K et al: Urinary tract infection in relation to diaphragm use and obesity. Int J Epidemiol. 1987 Sep;16(3):441-4. PMID 3667045.

125

Foxman B, Gillespie B, Koopman J et al: Risk factors for second urinary tract infection among college women. Am J Epidemiol. 2000 Jun 15;151(12):1194-205. PMID 10905532

126

Hooton TM, Hillier S, Johnson C et al: Escherichia coli bacteriuria and contraceptive method. JAMA 265: 64, 1991. PMID 1859519

127

Hooton TM, Roberts PL, Stamm WE: Effects of recent sexual activity and use of a diaphragm on the vaginal microflora. Clin Infect Dis. 1994 Aug;19(2):274-8. PMID 7986899

128

Weiss BD, Bassford T, Davis T: The cervical cap. Am Fam Physician. 1991 Feb;43(2):517-23. PMID 1990736

129

133. Yranski PA, Gamache ME: New options for barrier contraception. J Obstet Gynecol Neonatal Nurs. 2008 May-Jun;37(3):384-9. PMID 18507612

130

World Health Organization Department of Reproductive Health and Research (WHO/RHR) and Johns Hopkins Bloomberg School of Public Health/Center for Communication Programs (CCP), INFO Project. Family Planning: A Global Handbook for Providers. Baltimore and Geneva: CCP and WHO, 2007

131

Richwald MA, Greenland S, Gerber MM et al: Effectiveness of the cavity rim cervical cap: Results of a large clinical study. Obstet Gynecol 74: 143, 1989. PMID 2664609

132

Gallo MF, Grimes DA, Schulz KF: Cervical cap versus diaphragm for contraception. Cochrane Database Syst Rev. 2002;(4):CD003551

133

Mauck C, Callahan M, Weiner DH et al: A comparative study of the safety and efficacy of FemCap, a new vaginal barrier contraceptive, and the Ortho All-Flex diaphgram. The FemCap Investigators’ Group. Contraception. 1999 Aug;60(2)71-90. PMID 10592853

134

Mauck C, Glover LH, Miller E et al: Lea's Shield: a study of the safety and efficacy of a new vaginal barrier contraceptive used with and without spermicide. Contraception. 1996 Jun;53(6):329-35. PMID 8773419

135

Moench TR, Chipato T, Padian NS: Preventing disease by protecting the cervix: the unexplored promise of internal vaginal barrier devices. AIDS. 2001 Sep 7;15(13):1595-602. 11546933

136

Roddy RE, Zekeng L, Ryan KA et al: A controlled trial of nonoxynol 9 film to reduce male-to-female transmission of sexually transmitted diseases. N Engl J Med. 1998 Aug 20;339(8):504-10. PMID 9709043

137

Harvey SM, Beckman LJ, Murray J: Factors associated with use of the contraceptive sponge. Fam Plann Perspect 21: 779, 1989. PMID 2792337

138

Psychoyos A, Creatzas G, Hassan E et al: Spermicidal and antiviral properties of cholic acid: Contraceptive efficacy of a new vaginal sponge (Protectaid) containing sodium cholate. Hum Reprod 8: 866, 1993. PMID 7688380

139

Ayotte N, Colin P: Spermicidal activity of a new contraceptive sponge. Adv Ther. 2002 Sept-Oct;19(5):219-28. PMID 12539882

140

Kuyoh MA, Toroitich-Ruto C, Grimes DA et al: Sponge versus diaphragm for contraception: a Cochrane review. Contraception. 2003 Jan;67(1):15-8. PMID 12521652

141

Rosenberg MJ, Rojanapithayakorn W, Feldblum PJ et al: Effect of the contraceptive sponge on chlamydial infection, gonorrhea, and candidiasis. A comparative clinical trial. JAMA. 1987 May 1;257(17):2308-12. PMID 3033339

142

Rosenberg MJ, Davidson AL, Chen JH et al: Barrier contraceptives and sexually transmitted diseases in women: a comparison of female-dependent methods and condoms. Am J Public Health. 1992 May;82(5):669-74. PMID 1566944

143

Kreiss J, Ngugi E, Holmes K et al: Efficacy of nonoxynol-9 contraceptive sponge use in preventing heterosexual acquisition of HIV in Nairobi prostitutes. JAMA. 1992 Jul 22-29;268(4):477-82. PMID 1320133

144

Roddy RE, Cordero M, Cordero C et al: A dosing study of nonoxynol-9 and genital irritation. Int J STD AIDS. 1993 May-Jun;4(3):165-70. PMID 8391856

145

Faith G, Pearson K, Fleming D et al: Toxic shock syndrome and the vaginal sponge. JAMA. 1986 Jan 10;255(2):216-8. PMID 3001376

146

Speroff L, Darney PD: Barrier Methods of Contraception. In: A Clinical Guide for Contraception, 5th ed. Philadelphia: Wolters Kluwer Health/Lippincott Williams & Wilkins, 2011:281-313

147

Grimes DA, Lopez LM, Raymond EG et al: Spermicide used alone for contraception. Cochrane Database Syst Rev. 2013 Dec 5;12:CD005218. PMID 24307556

148

World Health Organiziation: WHO/CONRAD technical consultation on nonoxynol-9, World Health Organization, Geneva, 9-10 October 2001: summary report. Reprod Health Matters. 2002 Nov;10(20):175-81. PMID 12569895

149

Feldblum BJ, Morrison CS, Roddy RE et al: The effectiveness of barrier methods of contraception in preventing the spread of HIV. AIDS. 1995;9 Suppl A:S85-93. PMID 8819574

150

Nitruhisard S, Roddy RE, Chutivongse S: Use of nonoxynol-9 and reduction in rate of gonoccocal and chlamydial infections. Lancet. 1992 Jun 6;339(8806):1371-5. PMID 1350804

151

Obiero J, Mwethera PG, Wiysonge CS et al: Topical microbicides for prevention of sexually transmitted infections. Cochrane Database Syst Rev. 2012 Jun 13;6:CD007961. PMID 2269373

152

Huggins G, Vessey M, Flavel R et al: Vaginal spermicides and the outcome of pregnancy: Findings in a large cohort study. Contraception. 1982 Mar;25(3):219-30. PMID 7075194

153

Linn S, Schoenbaum SC, Monson RR et al: Lack of association between contraceptive usage and congenital malformations in offsprings. Am J Obstet. 1983 Dec 15;147(8):923-8. PMID 6650629

154

Louik CM, Mitchell AA, Werler MM et al: Maternal exposure to spermicides in relation to certain birth defects. N Engl J Med. 1987 Aug 20;317(8):474-8. PMID 2956519

155

Simpson JL, Phillips OP: Spermicides, hormonal contraception and congenital malformations. Adv Contraception. 1990 Sep;6(3):141-67. PMID 2248126

156

Einarson TR, Koren G, Maticce D et al: Maternal spermicide use and adverse reproductive outcome: A meta-analysis. Am J Obstet Gynecol. 1990 Mar;162(3):655-60. PMID 2138413

157

Gallaway MS, Waller DK, Canfield MA et al: The association between use of spermicides or male condoms and major structural birth defects. Contraception. 2009 Nov;80(5):422-9. PMID 19835715

158

Bracken MB: Spermicidal contraceptives and poor reproductive outcomes: the epidemiologic evidence against an association. Am J Obstet Gynecol. 1985 Mar 1;151(5):552-6. PMID 3883778

159

U.S. Food and Drug Administration: Data do not support association between spermicides, birth defects. FDA Bulletin. 1986 Nov;16(2):21. PMID 3817349

160

Hillier SL, Moench T, Shattock R et al: In vitro and in vivo: the story of nonoxynol 9. J Acquir Immune Defic Syndr. 2005 May 1;39(1):1-8. PMID 15851907

161

Wilkinson D, Ramjee G, Tholandi M et al: Nonoxynol-9 for preventing vaginal acquisition of sexually transmitted infections by women from men. Cochrane Database Syst Rev. 2002;(4):CD003939. PMID 12519623

162

Roddy RE, Zekeng L, Ryan KA et al: Effect of nonoxynol-9 gel on urogenital gonorrhea and chlamydial infection: a randomized controlled trial. JAMA. 2002 Mar 6;287(9):1117-22. PMID 11879108

163

Van Damme L, Ramjee G, Alary M et al: Effectiveness of COL-1492, a nonoxynol-9 vaginal gel, on HIV-1 transmission in female sex workers: a randomized controlled trial. Lancet. 2002 Sep 28;360(9338):971-7. PMID 12383665

164

Food and Drug Administration, HHS: Over-the-counter vaginal contraceptive and spermicide drug products containing nononynol 9; required labeling. Final rule. Fed Regist. 2007 Dec 19;72(243):71769-85. PMID 18159651

165

Poynten IM, Millwood IY, Falster, MO et al: The safety of candidate vaginal microbicides since nonoxynol-9: a systematic review of published studies. AIDS. 2009 Jun 19;23(10):1245-1254. PMID 19474652